Objective: This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic-to-pulmonary artery shunts in patients with pulmonary overcirculation.

Background: Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single-ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described.

Methods: Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic-to-pulmonary artery shunt with a covered stent in a Diabolo "hour-glass" configuration.

Results: From July 2018 to February 4, 2019, consecutive patients underwent trans-catheter downsizing of a systemic-to-pulmonary artery shunt. The median age was 3.3 years (range 0.7-5.7 years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo "hour-glass" configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29 mmHg (range 25-32 mmHg) to a median of 21 mmHg (range 14-27 mmHg).

Conclusions: Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts with a covered stent in a Diabolo configuration is safe and feasible. With this technique, the pulmonary blood flow can be adjusted in a physiologic closed-chest condition and further regulated over time.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.28598DOI Listing

Publication Analysis

Top Keywords

systemic-to-pulmonary artery
20
downsizing systemic-to-pulmonary
16
percutaneous intraluminal
12
artery shunts
12
pulmonary overcirculation
12
patients underwent
12
covered stent
12
stent diabolo
12
intraluminal downsizing
8
novel application
8

Similar Publications

Pulmonary atresia with ventricular septal defect (PA-VSD) is usually diagnosed by transthoracic or fetal echocardiography, with the prenatal diagnosis being feasible and accurate if fetal cardiology services are available. The limitations of transthoracic echocardiography (TTE) in the evaluation of PA-VSD include the complete evaluation of the pulmonary arteries and patent ductus arteriosus, quantitative evaluation of the right ventricle size and function, and delineation of associated cardiac anomalies such as coronary artery anomalies, anomalies of systemic or pulmonary venous return, and complex arch anomalies. Echocardiography also has limitations in evaluating hemodynamics such as flow volumes, shunts, and regurgitant fraction.

View Article and Find Full Text PDF

Although the corticosteroid betamethasone is routinely administered to accelerate lung and cardiovascular maturation in the preterm fetus prior to birth, and use of delayed cord clamping (DCC) is recommended at birth by professional bodies, it is unknown whether antenatal betamethasone alters perinatal pulmonary or systemic arterial blood flow accompaniments of DCC. To address this issue, preterm fetal lambs [gestation 127 (1) days, term = 147 days] with (n = 10) or without (n = 10) antenatal betamethasone treatment were acutely instrumented under general anaesthesia with flow probes to obtain left (LV) and right ventricular (RV) outputs, major central arterial blood flows and shunt flow across both the ductus arteriosus and foramen ovale (FO). After delivery, lambs underwent initial ventilation for 2 min prior to DCC.

View Article and Find Full Text PDF

Systemic-to-pulmonary collaterals (SPCs) are common in congenital heart disease (CHD). Particularly in single ventricle anatomy and Fontan circulation, SPC can both complicate the postoperative course and lead to clinical deterioration in the long term. The treatment of SPC is controversial.

View Article and Find Full Text PDF

The objective of this study is to evaluate the clinical application and primary outcome of transcatheter embolization using Amplatzer™ Vascular Plug (AVP) Type 2 and Type 4 in different congenital cardiovascular malformations. This is a single-center retrospective observational cohort study. We analyzed clinical and imaging data of 36 patients retrospectively who received transcatheter embolizations of the following malformations using AVP: systemic-to-pulmonary collateral arteries (SPCA), patent ductus arteriosus (PDA), ventricular septal defects (VSD), and aberrant pulmonary sequestration arteries (PSA).

View Article and Find Full Text PDF

Almost 20% of children with simple or complex types of CHD have a duct-dependent circulation The systemic-to-pulmonary shunt can be performed surgically, e.g., Blalock-Taussing shunt or with a patent duct arteriosus stenting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!