Oral candidiasis as a highly prevalent and recurrent infection in medically compromised individuals is mainly caused by the opportunistic fungal pathogen . This epithelial infection, if not controlled effectively, can progress to life-threatening systemic conditions and complications. The efficacy of current frontline antifungals is limited due to their poor bioavailability and systemic toxicity. As such, an efficient intervention is essential for controlling disease progression and recurrence. Herein, a theranostic nanoplatform (CD-Gu-AmB) was developed to track the penetration of antifungals and perturb the invasion of at oral epithelial tissues, via decorating the homemade red-emissive carbon dots (CD) with positively charged guanidine groups (Gu) followed by conjugation with antifungal polyene (amphotericin B, AmB) in a reacting site-controllable manner. The generated CD-Gu-AmB favorably gathered within the cells and exhibited potent antifungal effects in both planktonic and biofilm forms. It selectively accumulated in the nuclei of human oral keratinocytes and exhibited undetectable toxicity to the host cells. Moreover, we reported for the first time the penetration and exfoliation profiles of CD in a three-dimensional organotypic model of human oral epithelial tissues, demonstrating that the extra- and intracellular accumulation of CD-Gu-AmB effectively resisted the invasion of by forming a "shielding" layer throughout the entire tissue. This study establishes a multifunctional CD-based theranostic nanoplatform functioning as a traceable and topically applied antifungal to arm oral epithelia, thereby shedding light on early intervention of mucosal candidiasis for oral and general health.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.9b18003DOI Listing

Publication Analysis

Top Keywords

carbon dots
8
arm oral
8
oral epithelia
8
theranostic nanoplatform
8
oral epithelial
8
epithelial tissues
8
human oral
8
oral
7
red-emissive guanylated
4
guanylated polyene-functionalized
4

Similar Publications

Carbon dots in biosensing have advanced significantly, adding improvements to different detection techniques. In this study, an amperometric immunosensor for Salmonella Thyphimurium was designed using antibodies labeled with carbon dots (Cdots) from pequi almond (Caryocar brasiliensis). Cdots were synthesized by pyrolysis and characterized by FTIR, UV/fluorescence, electrochemistry, zeta potential, and transmission electron microscopy (TEM).

View Article and Find Full Text PDF

A sensitized dual-response ratiometric fluorescent sensor integrated smartphone platform for accurate discrimination and detection of tetracycline homologues based on N-CDs‒Eu complex.

Mikrochim Acta

January 2025

Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Education, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou, 310058, China.

A sensitized dual-response ratiometric fluorescent sensor integrated smartphone platform for accurate discrimination and detection of tetracycline (TC) homologues was fabricated based on N-CDs-Eu complex. In the sensing system, N-CDs act as a sensitizer of Eu and significantly enhance the fluorescence of TC-Eu complex approximate 40-fold owing to the synergistic effect of antenna effect (AE) and fluorescence resonance energy transfer (FRET). A paper sensor integrated with a smartphone platform is further fabricated for on-site measurement of TC.

View Article and Find Full Text PDF

Dual Ratiometric Fluorescence Sensors Based on Chiral Carbon Dots for the Sensitive and Specific Detection of Arginine.

Anal Chem

January 2025

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China.

Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.

View Article and Find Full Text PDF

In this study, we present an intelligent electromagnetic-actuated microfluidic chip integrated with a G-quadruplex DNAzyme-based biocatalysis platform for rapid and sensitive tetracycline (TC) detection. In this sensing system, TC significantly quenches fluorescent magnetic carbon dots (M-CDs) via the internal filtration effect and dynamic quenching (the excitation and emission wavelength at 350 and 440 nm, respectively). Then, the G-quadruplex on the M-CDs-Aptamer is exposed and bound with hemin to form hemin-G-quadruplex DNAzyme, catalyzing the conversion of 3,3',5,5'-tetramethylbenzidine to produce blue color.

View Article and Find Full Text PDF

Antibacterial carbon dots.

Mater Today Bio

February 2025

Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China.

Bacterial infections significantly threaten human health, leading to severe diseases and complications across multiple systems and organs. Antibiotics remain the primary treatment strategy for these infections. However, the growing resistance of bacteria to conventional antibiotics underscores the urgent need for safe and effective alternative treatments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!