Organotypic tumor slices represent a physiologically-relevant culture system for studying the tumor microenvironment. Systematic characterization of the tumor slice culture system will enable its effective application for translational research. Here, using flow cytometry-based immunophenotyping, we performed a comprehensive characterization of the immune cell composition in organotypic tumor slices prepared from four syngeneic mouse tumor models and a human liver tumor. We found that the immune cell compositions of organotypic tumor slices prepared on the same day as the tumor cores were harvested are similar. Differences were primarily observed in the lymphocyte population of a clinical hepatocellular carcinoma case. Viable populations of immune cells persisted in the tumor slices for 7 days. Despite some changes in the immune cell populations, we showed the utility of mouse tumor slices for assessing responses to immune-modulatory agents. Further, we demonstrated the ability to use patient-derived xenograft tumor slices for assessing responses to targeted and cytotoxic drugs. Overall, tumor slices provide a broadly useful platform for studying the tumor microenvironment and evaluating the preclinical efficacy of cancer therapeutics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6844320PMC
http://dx.doi.org/10.1080/2162402X.2019.1670019DOI Listing

Publication Analysis

Top Keywords

tumor slices
28
organotypic tumor
16
tumor
13
immune cell
12
tumor slice
8
culture system
8
studying tumor
8
tumor microenvironment
8
slices prepared
8
mouse tumor
8

Similar Publications

Objectives: The Scrotal and Penile Imaging Working Group (SPIWG) of the European Society of Urogenital Radiology (ESUR) aimed to formulate recommendations on the imaging modalities and minimal technical requirements for abdominopelvic imaging in the follow-up of adult patients treated for testicular germ-cell tumors (TGCT).

Methods: The SPIWG members performed an extensive literature search, reviewed the current clinical practice, and reached a consensus based on the opinions of experts in the field.

Results: Recurrence in patients treated for TGCT mainly occurs in retroperitoneal lymph nodes (LNs).

View Article and Find Full Text PDF

Intraoperative ultrasound (ioUS) provides real-time imaging during neurosurgical procedures, with advantages such as portability and cost-effectiveness. Accurate tumor segmentation has the potential to substantially enhance the interpretability of ioUS images; however, its implementation is limited by persistent challenges, including noise, artifacts, and anatomical variability. This study aims to develop a convolutional neural network (CNN) model for glioma segmentation in ioUS images via a multicenter dataset.

View Article and Find Full Text PDF

Background: Accurate prognostic models are essential for optimizing treatment strategies for glioblastoma, the most aggressive primary brain tumor. While other neuroimaging modalities have demonstrated utility in predicting overall survival (OS), intraoperative ultrasound (iUS) remains underexplored for this purpose. This study aimed to evaluate the prognostic potential of iUS radiomics in glioblastoma patients in a multi-institutional cohort.

View Article and Find Full Text PDF

Fast Hadamard-Encoded 7T Spectroscopic Imaging of Human Brain.

Tomography

January 2025

NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.

: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.

View Article and Find Full Text PDF

Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).

Methods: 148 patients (45 female, 65.1 ± 14.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!