A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety of Transesophageal Echocardiography Performed by Intensivists and Emergency Physicians in Critically Ill Patients With Coagulopathy and Thrombocytopenia: A Single-Center Experience. | LitMetric

Introduction: The use of transesophageal echocardiography (TEE) by intensivist physicians (IPs) and emergency physicians (EPs) in critically ill patients is increasing in the intensive care unit, emergency department, and prehospital environments. Coagulopathy and thrombocytopenia are common in critically ill patients. The risk of performing TEE in these patients is unknown. The goal of this study was to assess whether TEE is safe when performed by IPs or EPs in critically ill patients with high bleeding risk (HBR).

Methods: All TEEs performed by an IP or EP between January 1, 2016, and July 31, 2019, were reviewed as part of a quality assurance database. A TEE performed on a patient was deemed HBR if the patient met at least one of the following criteria: undergoing therapeutic anticoagulation, had an INR > 2, activated partial thromboplastin time >40 seconds, fibrinogen <150 mg/dL, and/or platelet count <50 000/μL. The medical record was reviewed on each patient to determine whether upper esophageal bleeding, oropharyngeal bleeding, esophageal perforation, or dislodgement of an artificial airway occurred during or after the TEE.

Results: A total of 228 examinations were reviewed: 80 in the high-risk group and 148 in the low-risk group (LBR). There were complications potentially attributable to TEE in 8 (4%) of the 228 exams. Total complications were not different between groups: 4 (5%) in the HBR group versus 4 (3%) in the LBR group (odds ratio [OR] = 1.89 [0.34-10.44], =.368). Upper esophageal bleeding occurred in 5 total examinations (2%), which was not different between groups: 3 (4%) in the HBR group and 2 (1%) in the LBR group (OR = 2.84 [0.31-34.55], = .238). There were no deaths attributable to TEE in either group.

Conclusion: Transesophageal echocardiography can be safely performed by IPs and EPs in critically ill patients at high risk of bleeding with minimal complications.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0885066619887693DOI Listing

Publication Analysis

Top Keywords

critically ill
16
ill patients
16
transesophageal echocardiography
8
emergency physicians
8
coagulopathy thrombocytopenia
8
eps critically
8
patients
5
safety transesophageal
4
performed
4
echocardiography performed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!