Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of this study was to compare measurements of macular thickness, obtained from patients with diabetic macular edema, using two spectral-domain optical coherence tomography (SD-OCT) devices. These were the Spectralis Heidelberg Retina Angiograph + Optical Coherence Tomography (HRA + OCT) (Heidelberg Engineering), which is often considered the gold-standard for OCT measurement, and the Spectral Optical Coherence Tomography/Scanning Laser Ophthalmoscopy (OCT/SLO) (Optos plc), which can additionally perform microperimetry, a useful measure of visual function. In this prospective observational study, each eye had SD-OCT performed with both devices on the same day by the same investigator. Mean retinal thickness was calculated, and compared between the devices, for central and parafoveal zones within 3 mm of the fovea. 62 eyes were included. In the central, superior, temporal, inferior and nasal zones respectively, mean retinal thickness with Spectralis HRA+OCT was (in microns) 310, 343, 344, 332 and 340; measurements with Spectral OCT/SLO were 237, 298, 297, 289 and 290. Pearson correlations between the devices were 0.752, 0.85, 0.928, 0.839, and 0.823 (p < 0.0001). Although absolute measurements between the devices were significantly different and therefore not interchangeable, the correlation between the devices was over 75% and statistically significant in all zones. Thus, the Spectral OCT/SLO could reliably be used for SD-OCT in patients who may also require microperimetry assessment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849021 | PMC |
http://dx.doi.org/10.3390/vision1010002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!