The Development of the Overstitch System and Its Potentials.

Gastrointest Endosc Clin N Am

301 St Paul Place POB, Suite 718, Baltimore, MD 20202, USA. Electronic address:

Published: January 2020

Endoscopic suturing device for flexible endoscopy was conceptualized by Apollo Group in collaboration with Olympus Optical Ltd. The first modification of suturing device for flexible endoscopy (Eagle Claw) was manufactured by Olympus engineers and extensively used by members of Apollo Group in numerous bench-top experiments on isolated pig stomachs and in live porcine model. The suturing system for flexible endoscopy in humans (Overstitch) was cleared for general clinical use in the United States in 2008. The latest model is compatible with more than 20 single-channel flexible endoscopes with diameters ranging from 8.8 mm to 9.8 mm made by major endoscope manufacturers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.giec.2019.08.004DOI Listing

Publication Analysis

Top Keywords

flexible endoscopy
12
suturing device
8
device flexible
8
apollo group
8
development overstitch
4
overstitch system
4
system potentials
4
potentials endoscopic
4
endoscopic suturing
4
flexible
4

Similar Publications

Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Since abdominal adhesion are quite problematic in abdominal and pelvic surgery, the conventional HA/CMC film are commonly used as an anti-adhesive material. However, such types are difficult to be rolled and delivered through the port of laparoscopic surgical devices due to adherence to the laparoscopic port or other parts of the films. To create an anti-adhesion film with more favorable handling properties and anti-adhesive effect, we developed a novel punctate uneven gelatin film (PU GF).

View Article and Find Full Text PDF

When a difficult airway is anticipated, awake tracheal intubation can be considered. Usually, low doses of sedatives are administered during this procedure for minimal sedation and anxiolysis, such as midazolam and remifentanil. The newly developed ultra-short-acting benzodiazepine remimazolam has a pharmacokinetic profile that is more suitable for titration during awake tracheal intubation than the long-acting midazolam.

View Article and Find Full Text PDF

Aim: To evaluate the efficacy of flexible ureteroscopic lithotripsy (FURL) and extracorporeal shock wave lithotripsy (ESWL) in the treatment of ureteral calculi based on decision tree model.

Methods: A total of 600 patients with ureteral calculi, including 289 treated with FURL and 311 cases with ESWL in Anqing Municipal Hospital from June 2021 to August 2023, were selected as study subjects. Perioperative indicators and stone clearance rate of the two groups were compared, and the preoperative and postoperative (24 and 72 hours) changes of serum creatinine, cystatin C (Cys-C) and microalbumin were observed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!