Objectives: In partial mastectomy (PM) or lumpectomy, ultrasound (US) localization avoids discomfort and additional procedures associated with wire localization. The purpose of this study was to evaluate the association between ultrasound-visible clip (UVC) use at the time of biopsy and US use during resection, hypothesizing that UVCs facilitate US localization and reduce costs compared with traditional radiopaque clips or no clip placement.

Methods: The study population consisted of adult female patients with breast cancer undergoing PM or lumpectomy at our institution between 2014 and 2016. The core biopsy clip type and localization method during PM were characterized as wire localization versus US localization, and associations were estimated with multivariable regression models. For the cost evaluation, breast biopsy data were obtained from the Department of Radiology.

Results: Among 674 patients, 490 had data on localization and the clip type. Ultrasound-visible clip placement at biopsy increased US use during resection by 13% (95% confidence interval, 6%-21%). There was no difference in the total specimen weight with US versus wire localization. The cost savings for using UVCs for the 2209 patients who underwent breast biopsy from 2014 to 2016 was $36,000.

Conclusions: This study demonstrates that US localization for PM is feasible at a single institution and cost-effective when facilitated by UVCs. Placement of a UVC at the time of biopsy is recommended, as it is cost-effective and avoids the discomfort and inconvenience of wire localization.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jum.15172DOI Listing

Publication Analysis

Top Keywords

wire localization
16
ultrasound-visible clip
12
localization
11
breast cancer
8
avoids discomfort
8
uvc time
8
time biopsy
8
2014 2016
8
clip type
8
breast biopsy
8

Similar Publications

Hydrogen peroxide (HO) is a critical signaling molecule with significant roles in various physiological processes in plants. Understanding its regulation through in situ monitoring could offer deeper insights into plant responses and stress mechanisms. In this study, we developed a microneedle electrochemical sensor to monitor HO in situ, offering deeper insights into plant stress responses.

View Article and Find Full Text PDF

Background: Most breast cancers are detected at an early stage in which case conservative surgery is indicated. An accurate preoperative localization technique is essential for conservative surgery of non-palpable breast lesions. Currently, the gold standard technique is wire localization (WL).

View Article and Find Full Text PDF

Comparative analysis of cavitation erosion behavior in wire-arc directed energy deposition and cast nickel-aluminum bronze alloys.

Ultrason Sonochem

January 2025

Jiangsu Key Laboratory for Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China.

In this study, the cavitation erosion (CE) behavior of wire-arc directed energy deposition (DED) nickel-aluminum bronze (NAB) alloys is compared with that of cast alloys, and the synergistic effect between corrosion and CE is investigated. The CE resistance of the wire-arc DED NAB alloy is better than that of the cast alloys. The CE of NAB alloys preferentially occurs at the boundaries of the α-Cu and residual β phases, and in the matrix around the κ phase.

View Article and Find Full Text PDF

Prone Transpsoas Lumbar Interbody Fusion for Degenerative Disc Disease.

JBJS Essent Surg Tech

January 2025

Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.

Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.

View Article and Find Full Text PDF

A comparative study of 4-hook anchor device with methylene blue for preoperative pulmonary nodule localization.

Quant Imaging Med Surg

January 2025

Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Accurate localization of small pulmonary nodules (SPNs) during video-assisted thoracoscopic surgery (VATS) is challenging due to the small size and deep location. Both the 4-hook wire technique and methylene blue are significant methods for preoperative localization of SPNs. This study aimed to compare the safety of both methods by monitoring and recording any surgery-related complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!