Background: Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied.

Objective: We wanted to compare three DOAC agents with warfarin during cardiac device implantation.

Methods: Consecutive patients on treatment with dabigatran, rivaroxaban, or apixaban (group A) undergoing a cardiac device generator change, upgrade, or new implantation procedure were compared to those on warfarin (group B). Incidence of hematoma, infection, effusion, stroke, and other complications were noted at 1 day, 1 week, and 3 months.

Results: A total of 311 patients in group A underwent the above procedures with 73 patients on dabigatran, 153 on rivaroxaban, and 85 on apixaban. There were 467 patients on warfarin in group B. Mean age of the total population was 68 ± 12 years with 67% males and > 80% Caucasians. The last dose of the DOAC was the night prior to the procedure and resumed the night of the procedure (single dose interruption for apixaban and dabigatran and no un-interruption for rivaroxaban). There was no difference noted in the incidence of minor or major hematoma (9% vs 8.5%, p = 0.7). No stroke occurred in either group.

Conclusion: Use of DOAC agents with transient interruption of one dose is as safe as warfarin in the peri-procedural setting during implantation of cardiac devices.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-019-00646-4DOI Listing

Publication Analysis

Top Keywords

cardiac device
12
cardiac devices
8
peri-procedural setting
8
doac agents
8
rivaroxaban apixaban
8
warfarin group
8
warfarin
6
cardiac
5
peri-procedural direct
4
direct anticoagulation
4

Similar Publications

Stent Graft Migration Causing Two Aortic Wall Injuries 10 Years After Type II Hybrid Arch Repair.

Ann Thorac Surg Short Rep

September 2023

Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada.

Hybrid arch repair (HAR) combines surgical reconstruction of the ascending aorta and arch debranching with stent graft deployment into the descending thoracic aorta in an effort to reduce the morbidity associated with conventional open total arch replacement. We describe a case of delayed presentation for 2 thoracic aortic wall injuries caused by stent graft migration after type II HAR. This report highlights an important late complication of HAR and the need for careful device selection.

View Article and Find Full Text PDF

Context: Heart rate (HR) is the most vital parameter to assess hemodynamic transition at birth. ECG is considered a gold standard for HR assessment. New devices with dry electrodes are easy to apply on a wet newborn.

View Article and Find Full Text PDF

The mortality rate of postcardiotomy cardiogenic shock after cardiovascular surgery is quite high, and the only way to avoid this serious complication is to initiate a preemptive strategy during surgery. The Impella 5.5 device with the SmartAssist system (Abiomed) is mainly used to prevent or to treat cardiogenic shock in cardiac surgery, but it is not often used in aortic surgery.

View Article and Find Full Text PDF

"Swiss-cheese" ventricular septal defects present complex treatment challenges. Despite difficult defect visualization and closure, complete septation is the treatment of choice. We present the case of a 2-year-old with residual apical "Swiss-cheese" ventricular septal defects after failed percutaneous device closure with 2 occluder devices.

View Article and Find Full Text PDF

Purpose: To report the outcomes of the early feasibility study of transapical transcatheter mitral valve replacement (TMVR) with the SATURN System (InnovHeart, Milano, Italy) to treat patients with severe functional mitral regurgitation.

Description: Five high surgical risk patients underwent transapical transcatheter mitral valve replacement with the SATURN System at a single center. One-year follow-up is complete for all patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!