A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluoride Release from Two High-Viscosity Glass Ionomers after Exposure to Fluoride Slurry and Varnish. | LitMetric

Fluoride Release from Two High-Viscosity Glass Ionomers after Exposure to Fluoride Slurry and Varnish.

Materials (Basel)

Department of Biomedical Sciences and Comprehensive Care, School of Dentistry, Indiana University, 1121 West Michigan Street, Indianapolis, IN 46202, USA.

Published: November 2019

The effect of brushing with different fluoride slurries on the fluoride release (FR) of different high-viscosity glass ionomer cements (GICs) was investigated. Fifty-eight discs were fabricated from two high-viscosity GICs (GC Fuji IX (F9) and 3M ESPE Ketac-fil (KF)). Five specimens from each brand were used to measure Vickers microhardness and the remaining were randomly assigned to one of four groups ( = 6) based on two-factor combinations: (1) fluoride concentration in the abrasive slurry (275 or 1250 ppm fluoride as NaF) and (2) immersion in a 22,500 ppm fluoride-containing solution. Specimens were brushed for a total of 20,000 strokes over 4 days with daily FR measurement. Data were analyzed using analysis of variance and Bonferroni tests (α = 0.05). Baseline FR and microhardness values were different between the two tested material brands. Exposure to a 22,500 ppm solution was associated with higher FR but not the exposure to 1250 ppm slurries. Brushing and immersion of glass ionomer cements in a 22,500 ppm F solution led to higher FR that was more sustained for KF. Type of the glass ionomer, progressive brushing, and fluoride varnish affected FR but not the fluoride content in the abrasive slurry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888192PMC
http://dx.doi.org/10.3390/ma12223760DOI Listing

Publication Analysis

Top Keywords

glass ionomer
12
22500 ppm
12
fluoride
8
fluoride release
8
release high-viscosity
8
high-viscosity glass
8
brushing fluoride
8
ionomer cements
8
abrasive slurry
8
1250 ppm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!