A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A development of high-throughput HPLC method for the polysorbate 80 quantitation in protein therapeutic products. | LitMetric

A development of high-throughput HPLC method for the polysorbate 80 quantitation in protein therapeutic products.

J Chromatogr B Analyt Technol Biomed Life Sci

International Biotechnology Center "Generium", Vladimirskaya str., 14, Petushinskiy District, 601125 Vladimir Region, Russia.

Published: December 2019

A quantitative analysis of polysorbate 80 is an essential part of a characterization of therapeutic protein products. There are many methods to perform such type of analysis, including spectrophotometry and HPLC. However, there is no high-throughput method with high sensitivity and accuracy. In our work, we optimized conditions of polysorbate 80 hydrolysis to reduce the sample preparation time and developed a new isocratic reversed phase HPLC method for the quantification of oleic acid, the principal product of the hydrolysis. The validation of developed method shows that it is characterized by the repeatability less than 2.7% with the LOD about 25 ng (125 ppb), LOQ about 100 ng (500 ppb) within the analytical range of 0.025 to 1.5 mg/ml polysorbate 80 concentrations, accuracy between 92and108% and high precision (coefficient of variation less than3.2%). The total time needed for the analysis was about 1 h. The method could be routinely used for the quality control during therapeutic proteins manufacturing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2019.121847DOI Listing

Publication Analysis

Top Keywords

hplc method
8
method
5
development high-throughput
4
high-throughput hplc
4
polysorbate
4
method polysorbate
4
polysorbate quantitation
4
quantitation protein
4
protein therapeutic
4
therapeutic products
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!