Background: The operating room is the most cost consuming area of hospitals. However, it still suffers from a non-optimized organization.

Aim: To evaluate the performance of our operating rooms by the real room occupancy time (RROT), to identify the main causes of its alteration and to analyze the problem of deprogramming.

Methods: This is an observational and descriptive study conducted in two operating rooms in Sahloul teaching Hospital during August 2016. For the two studied rooms, a pre-established data sheet was filled during the days of scheduled activity. Collected parameters were  total RROT,  different periods of RROT, room occupancy rate, room overflow rate, incidence and causes of non-compliance with the surgical program and causes of RROT alteration.

Results:   The mean start time of the activity was 41.93 min/day. The mean overflow time was 11.51 min/day. The RROT was 246.56 min/day, corresponding to an average occupancy rate of 68.49%. On average 1.86 acts were performed per room and per morning with a total of 86 interventions. The deprogramming problem was noted in 38 cases. Its main causes were the overshoot of the vacation time offered to surgeons (36.84%), the emergencies (18.42%) and the non-respect of the anesthesia instructions (15.78%).

Conclusion: The occupancy rate in our structures is relatively acceptable but should not hide the need to optimize the use of available resources. Corrective actions focusing primarily on delayed start-up and periodic reassessments are essential.

Download full-text PDF

Source

Publication Analysis

Top Keywords

room occupancy
12
occupancy rate
12
operating room
8
operating rooms
8
room
7
time
5
occupancy
5
assessment operating
4
room efficiency
4
efficiency real
4

Similar Publications

Purpose: To explore if patients' preferences regarding formalities and inpatient accommodation during their inpatient hospital experience have changed since 1999.

Methods: A ten-item survey was administered to an inpatient sample in an urban teaching hospital and compared with results from a similar survey in 1999.

Results: The majority (98.

View Article and Find Full Text PDF

Salts of 2-amino-5-iodo-pyridinium.

Acta Crystallogr E Crystallogr Commun

October 2024

Carlson School of Chemistry and Biochemistry, Clark University, 950 Main St., Worcester, MA 01610, USA.

Reaction of 2-amino-5-iodo-pyridine (5IAP) with concentrated HBr at room temperature yielded 2-amino-5-iodo-pyridinium bromide, CHIN ·Br or (5IAPH)Br. The complex formed pale-yellow crystals, which exhibit significant hydrogen bonding between the amino and pyridinium N-H donors and bromide ion acceptors. Halogen bonding is also observed.

View Article and Find Full Text PDF

Bipolar Ionization Did Not Reduce Airborne Bacteria in a Lecture Hall.

ACS EST Air

December 2024

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Ionization treatment of indoor air has attracted attention for its potential to inactivate airborne pathogens and reduce disease transmission, yet its real-world effectiveness remains unverified. We evaluated the impact of an in-duct, bipolar ionization system on airborne particles, including culturable bacteria, in a lecture hall. The ionizer was off with variable fan speed for 1 week, on with variable fan speed for a second week, and on with high and constant fan speed for a third week.

View Article and Find Full Text PDF

Improving life quality for the aged: a comprehensive post-occupancy evaluation of long-term care facilities in China.

Front Public Health

December 2024

Institute of Architectural Design and Theoretical Research, Zhejiang University, Hangzhou, China.

Article Synopsis
  • - The text addresses the growing concern of improving living conditions for older adults in long-term care facilities (LTCFs) in China, highlighting the rapid development of such facilities and their often subpar physical environments that affect residents' quality of life.
  • - The study evaluated 37 LTCFs through post-occupancy evaluations (POEs) using tailored assessment tools and user feedback, revealing significant deficiencies in areas like outdoor spaces, resident rooms, and staff areas, indicating unmet psychological and operational needs.
  • - Ninety-two common issues were identified across eight categories, with discussions on their causes linked to various stages of facility development, aiming to inform future designs and contribute to better standards for LTCF construction.
View Article and Find Full Text PDF

This work is an application of experimental temperature data previously collected in a residential building in Douala, Cameroon, in order to analyze thermal discomfort. The data was collected according to three occupancy scenarios over 12 month period using thermohygrometer sensors. The temperature data are analysed in comparison with the comfortable temperature range from 24°C to 28°C.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!