Light-based monitoring devices to assess range use by laying hens.

Animal

School of Veterinary Sciences, University of Bristol, Langford House, Langford BS40 5DU, United Kingdom.

Published: April 2020

Access to an outdoor range has many potential benefits for laying hens but range use can be poor due to factors only partly understood. Techniques to monitor individual range use within commercial flocks are crucial to increase our understanding of these factors. Direct observation of individual range use is difficult and time-consuming, and automatic monitoring currently relies on equipment that is difficult to use in an on-farm setting without itself influencing range use. We evaluated the performance of a novel small, light and readily portable light-based monitoring system by validating its output against direct observations. Six commercial houses (2000 hens/house) and their adjacent ranges were used, three of which were equipped with more structures on the range than the others (to determine whether cover would influence monitoring accuracy). In each house, 14 hens were equipped with light monitoring devices for 5 discrete monitoring cycles of 7 to 8 consecutive days (at 20, 26, 32, 36 and 41 weeks of age). Light levels were determined each minute: if the reading on the hen-mounted device exceeded indoor light levels, the hen was classified as outside. Focal hens were observed directly for 5 min/hen per week. Accuracy (% of samples where monitoring and direct observations were in agreement) was high both for ranges with more and with fewer structures, although slightly better for the latter (92% v. 96% ± 1 SEM, F1,19 = 5.2, P = 0.034). Furthermore, accuracy increased over time (89%, 94%, 95%, 98% ± 1 SEM for observations at 26, 32, 36 and 41 weeks, respectively, F3,19 = 3.2, P = 0.047), probably due to progressively reduced indoor light levels resulting from partial closing of ventilation openings to sustain indoor temperature. Light-based monitoring was sufficiently accurate to indicate a tendency for a greater percentage of monitored time spent outside when more range structures were provided (more: 67%, fewer: 56%, SEM: 4, $\chi_1^2 = 2.9$, P = 0.089). Furthermore, clear and relatively consistent individual differences were detected. Individuals that were caught outside at the start of the experiment ranged more throughout its duration (caught outside: 72%, caught inside 51%, SEM: 4, $\chi_1^2 = 10.0$, P = 0.002), and individual range use was correlated between monitoring cycles (for adjacent monitoring cycles: $r_s^2 = 0.5-0.7$, P < 0.0001). This emphasizes the importance of studying range use on an individual level. In conclusion, our light-based monitoring system can assess individual range use accurately (although accuracy was affected by house characteristics to some extent) and was used to show that both cover availability and individual characteristics affected range use.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1751731119002830DOI Listing

Publication Analysis

Top Keywords

light-based monitoring
16
individual range
16
range
12
monitoring cycles
12
light levels
12
monitoring
10
monitoring devices
8
laying hens
8
monitoring system
8
direct observations
8

Similar Publications

For noninvasive light-based physiological monitoring, optimal wavelengths of individual tissue components can be identified using absorption spectroscopy. However, because of the lack of sensitivity of hardware at longer wavelengths, absorption spectroscopy has typically been applied for wavelengths in the visible (VIS) and near-infrared (NIR) range from 400 to 1,000 nm. Hardware advancements in the short-wave infrared (SWIR) range have enabled investigators to explore wavelengths in the ~1,000 nm to 3,000 nm range in which fall characteristic absorption peaks for lipid, protein, and water.

View Article and Find Full Text PDF
Article Synopsis
  • Advances in monitoring electrical signals in biosensing are essential, and current organic materials have limitations in spatial resolution and recording density.
  • The introduction of organic electro-scattering antennas (OCEANs) allows for wireless, light-based electrical signal probing with micrometer spatial resolution across potentially thousands of sites.
  • OCEANs achieve high signal-to-noise ratios, rapid time constants, and long-term stability, significantly improving the ability to record and analyze biological signals continuously.
View Article and Find Full Text PDF

Background: The aim of the study was to capture images that form on the human retina after the simulated implantation of an intraocular lens (IOL). White light was used rather than the commonly used near-infrared light, which is unsuitable for the examination of diffractive IOLs. For this purpose, a special optical setup was developed to investigate the influence of the IOL design on two-dimensional retinal images .

View Article and Find Full Text PDF

Advancements in 3D skin bioprinting: processes, bioinks, applications and sensor integration.

Int J Extrem Manuf

February 2025

Engineering Science and Mechanics Department, Penn State University, University Park, PA, United States of America.

This comprehensive review explores the multifaceted landscape of skin bioprinting, revolutionizing dermatological research. The applications of skin bioprinting utilizing techniques like extrusion-, droplet-, laser- and light-based methods, with specialized bioinks for skin biofabrication have been critically reviewed along with the intricate aspects of bioprinting hair follicles, sweat glands, and achieving skin pigmentation. Challenges remain with the need for vascularization, safety concerns, and the integration of automated processes for effective clinical translation.

View Article and Find Full Text PDF

Next-Gen Poly(ε-Caprolactone) Scaffolds: Non-Destructive In Vivo Monitoring and Accelerated Biodegradation.

Adv Healthc Mater

January 2025

Polymer Chemistry and Biomaterials Group, Department of Organic and Macromolecular Chemistry, Centre of Macromolecular Chemistry, Ghent University, Krijgslaan 281, Building S4, Belgie, Ghent, 9000, Belgium.

Poly(ɛ-caprolactone) (PCL) is a biocompatible, biodegradable, and highly mechanically resilient FDA-approved material (for specific biomedical applications, e.g. as drug delivery devices, in sutures, or as an adhesion barrier), rendering it a promising candidate to serve bone tissue engineering.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!