A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of LC-MS/MS methods to measure tobramycin and lincomycin in plasma, microdialysis fluid and urine: application to a pilot pharmacokinetic research study. | LitMetric

Background The aim of our work was to develop and validate a hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry (HILIC-ESI-MS/MS) methods for the quantification of tobramycin (TMC) and lincomycin (LMC)in plasma, microdialysis fluid and urine. Methods Protein precipitation was used to extract TMC and LMC from plasma, while microdialysis fluid and urine sample were diluted prior to instrumental analysis. Mobile phase A consisted of 2 mM ammonium acetate in 10% acetonitrile with 0.2% formic acid (v/v) and mobile phase B consisted of 2 mM ammonium acetate in 90% acetonitrile with 0.2% formic acid (v/v). Gradient separation (80%-10% of mobile phase B) for TMC was done using a SeQuant zic-HILIC analytical guard column. While separation of LMC was performed using gradient elution (100%-40% of mobile phase B) on a SeQuant zic-HILIC analytical column equipped with a SeQuant zic-HILIC guard column. Vancomycin (VCM) was used as an internal standard. A quadratic calibration was obtained over the concentration range for plasma of 0.1-20 mg/L for TMC and 0.05-20 mg/L for LMC, for microdialysis fluid of 0.1-20 mg/L for both TMC and LMC, and 1-100 mg/L for urine for both TMC and LMC. Results For TMS and LMC, validation testing for matrix effects, precision and accuracy, specificity and stability were all within acceptance criteria of ±15%. Conclusions The methods described here meet validation acceptance criteria and were suitable for application in a pilot pharmacokinetic research study performed in a sheep model.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2019-0780DOI Listing

Publication Analysis

Top Keywords

microdialysis fluid
16
mobile phase
16
plasma microdialysis
12
fluid urine
12
tmc lmc
12
sequant zic-hilic
12
application pilot
8
pilot pharmacokinetic
8
pharmacokinetic study
8
phase consisted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!