Some blood vessels enter bones through foramina, leaving the size of the foramen as a gauge for estimating the rate of blood flow and hence the metabolic rate of the supplied tissues. Foramen dimensions have been measured using varied methods in previous foramen studies, to relate regional blood flows with associated physiological processes. With the increasing interests in this 'foramen technique', standard methods with minimized measurement errors are therefore required. This study provides details of microphotographic and micro-computerized tomographic methods, and introduces a new alternative method, which uses impression material to measure foramen dimensions. The three methods are compared and the results indicate that all of them are capable of obtaining precise and accurate foramen dimension values, although they all have limitations. A microphotograph of the external opening is suggested to be the standard method because of its ease of use, but the alternative methods provide more detailed information on foramen shape. If the foramen is mainly occupied by one artery, blood flow rates can be calculated from foramen size and artery wall-lumen ratio, which is evaluated from the literature survey in this study. If veins or nerves also penetrate the foramen, a relative index of blood flow rate is nevertheless possible for comparative purposes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6956440 | PMC |
http://dx.doi.org/10.1111/joa.13106 | DOI Listing |
We present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.
View Article and Find Full Text PDFEur J Clin Invest
January 2025
Department of Surgical, Medical and Molecular Pathology and Critical Area, Laboratory of Biochemistry, University of Pisa, Pisa, Italy.
Sotatercept binds free activins by mimicking the extracellular domain of the activin receptor type IIA (ACTRIIA). Additional ligands are BMP/TGF-beta, GDF8, GDF11 and BMP10. The binding with activins leads to the inhibition of the signalling pathway and the deactivation of the bone morphogenic protein (BMP) receptor type 2.
View Article and Find Full Text PDFXenotransplantation
January 2025
Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA.
Advancements in xenotransplantation intersecting with modern machine perfusion technology offer promising solutions to patients with liver failure providing a valuable bridge to transplantation and extending graft viability beyond current limitations. Patients facing acute or acute chronic liver failure, post-hepatectomy liver failure, or fulminant hepatic failure often require urgent liver transplants which are severely limited by organ shortage, emphasizing the importance of effective bridging approaches. Machine perfusion is now increasingly used to test and use genetically engineered porcine livers in translational studies, addressing the limitations and costs of non-human primate models.
View Article and Find Full Text PDFArtif Organs
January 2025
Laboratory for Immune Response and Regulatory Medicine, Fujita Health University School of Medicine, Toyoake, Japan.
Background: The pathogenesis of sepsis is thought to be linked to a dysregulated immune response, particularly that involving neutrophils. We have developed a granulocyte adsorption column as a "decoy organ," which relocates the massive inflammation in organs in the body to a blood purification column. This study was conducted to assess the safety and experimental effectiveness of granulocyte monocyte adsorption apheresis-direct hemoperfusion (G1-DHP) in the treatment of patients with sepsis, using a prospective, multicenter design.
View Article and Find Full Text PDFJ Biophotonics
January 2025
Department of Emergency, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.
The brain, as a vital part of central nervous system, receives approximately 25% of body's blood supply, making accurate monitoring of cerebral blood flow essential. While fNIRS is widely used for measuring brain physiology, complex tissue structure affects light intensity, spot size, and detection accuracy. Many studies rely on simulations with limited experimental validation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!