Purpose: The aim of this study was to explore the surface roughness and hardness of the implant head of orthodontic mini-implants made from different alloys before and after their in vitro exposure to agents for prevention of gingivitis, mucositis, and peri-implantitis: chlorhexidine and probiotics.
Materials And Methods: Three types of commercially available mini-implants were tested: 316 stainless steel, titanium Grade 5, and titanium Grade 23 (both Ti-6Al-4V alloys with the same atomic weight percentage of Ti, Al, and V, with the difference being in maximal reduction of O in Grade 23 to 0.13% of atomic weight). They were immersed in three experimental solutions: artificial saliva, saliva with probiotic bacteria Lactobacillus reuteri, and saliva with oral antiseptic chlorhexidine (CHX). Samples were immersed for 28 days, thermocycled, then stored in an incubator at 37°C. Surface roughness and microhardness on five samples of each of the three implant types were measured by atomic force microscopy and the Vickers method, respectively.
Results: Exposure of titanium implant Grade 5 to probiotics significantly increased roughness compared with other media (P < .005). Exposure to CHX significantly increased the roughness of steel implants (P < .05). Neither saliva, probiotic, nor CHX altered microhardness of titanium implants significantly. In steel implants, the exposure to CHX and probiotics decreased microhardness compared with unexposed implants (P < .031), but not in comparison to saliva.
Conclusion: Probiotics seem to increase roughness of titanium mini-implants, while CHX seems to increase roughness of steel mini-implants. Only stainless steel implants had an altered, decreased hardness after exposure to CHX, although the same was found after their exposure to saliva. For patients undergoing orthodontic treatment with temporary anchorage units, CHX could be recommended for titanium, and probiotics for stainless steel mini-implants in oral-hygiene maintenance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.7392 | DOI Listing |
J Med Microbiol
January 2025
Institute of Advanced Study in Science and Technology (IASST), Guwahati 781035, Assam, India.
Cold atmospheric plasma (CAP) has emerged as a promising technology for neutralizing microbes, including multidrug-resistant strains. This study investigates CAP's potential as an alternative to traditional antimicrobial drugs for microbial inactivation. In the era of increasing antimicrobial resistance, there is a persistent need for alternative antimicrobial strategies.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
January 2025
Qingdao Qingli Environmental Protectionquipmen Co, LTD, Jiaozhou, 266300, China.
With the growing demand for nickel in the stainless steel and battery industries, conventional methods of extracting nickel from ores face challenges such as high production costs and environmental concerns. This study proposes a new process for the recovery of nickel metal and the production of nickel-iron alloys from nickel-bearing scrap. The reduction rates of nickel and iron oxides were investigated by optimizing the roasting temperature, time, and C/O ratio, and the process was optimized using response surface methodology (RSM).
View Article and Find Full Text PDFLangmuir
January 2025
Department of Polymer and Materials Chemistry, Faculty of Chemistry & Petroleum Sciences, Shahid Beheshti University, P.O. Box 1983969411 Tehran, Iran.
Liposomes are highly beneficial nanocarrier systems due to their biocompatibility, low toxicity, and exceptional inclusiveness, which lead to improved drug bioavailability. For biological applications, accurate control over these nanoparticles' mean size and size distribution is essential. Micromixers facilitate the continuous production of liposomes, enhancing the precision of size regulation and reproducibility.
View Article and Find Full Text PDFMicrosc Res Tech
January 2025
Faculty of Dental Medicine, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania.
One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
The aging population necessitates a critical need for medical devices, where polymers-based surface lubrication coating is essential for optimal functionality. In fact, lubrication and mechanical requirements vary depending on the service environment of different medical devices. Until now, key mean is still blank for general preparation of hydrophilic polymers-based lubrication coatings with on-demand mechanics and lubricity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!