A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Distinguishing Four HCV Genotypes by Loop Mediated Isothermal Amplification Assay. | LitMetric

Background: Genotyping of hepatitis C virus (HCV) is of great significance for clinical diagnosis and treatment. The object of this work was to establish a loop-mediated isothermal amplification (LAMP) method for four subtypes of HCV prevalent in China.

Methods: Gene sequences of HCV-1b, 2a, 3, and 6a were downloaded from Genebank. Primer sets of the four HCV subtypes for LAMP method were designed by Primer Explorer V.4. LAMP reactions were performed at 65°C for 60 minutes. Sera of HCV-1b, 2a, 3, and 6a, HBV-A, HBV-B, HIV-1, HIV-2 and HAV, synthesized nucleic acid of HCV-4a, and 5a were used for evaluation of LAMP performance. For specificity evaluation, each primer set for HCV-1b, 2a, 3, and 6a was tested with all kinds of sera. Each serum of the above 4 HCV subtypes was diluted and aliquoted into 10 parts. RNA was subsequently extracted, which was detected by LAMP and Real-time PCR to verify limit of detection (LOD).

Results: The LAMP assay established in this study could detect and distinguish HCV-1b, 2a, 3, and 6a. Consistent with gene sequencing methods, specificity of HCV-1b, 2a, 3, and 6a was 100%, 85%, 90%, and 100% detected by LAMP, respectively. The LOD of HCV-1b, 3, and 6a was 1.5 x 103 IU/mL. The LOD of HCV2a was 1.0 x 103 IU/mL with the LAMP method.

Conclusions: The LAMP method established in this study is feasible for distinguishing HCV-1b, 2a, 3, and 6a specifically and sensitively.

Download full-text PDF

Source
http://dx.doi.org/10.7754/Clin.Lab.2019.190142DOI Listing

Publication Analysis

Top Keywords

lamp method
12
lamp
9
isothermal amplification
8
hcv subtypes
8
detected lamp
8
established study
8
103 iu/ml
8
hcv-1b
7
distinguishing hcv
4
hcv genotypes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!