A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionni6hkqe6k2bbcho6vnic6inm0ddu4cfh): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative adverse events and early outcomes of custom-made fenestrated stent grafts and physician-modified stent grafts for complex aortic aneurysms. | LitMetric

AI Article Synopsis

  • The study focuses on the effectiveness and safety of physician-modified fenestrated stent grafts (PMSGs) and custom-made fenestrated stent grafts (CMSGs) for treating complex abdominal and thoracoabdominal aortic aneurysms (AAAs).
  • It analyzed 97 patients who underwent endovascular repair, noting differences in patient risk factors and outcomes between the two types of grafts used.
  • Results indicated that while CMSGs had lower in-hospital mortality (4% vs. 14%) and fewer complications, PMSGs had a higher proportion of severe cases and overall reintervention rates.

Article Abstract

Objective: Physician-modified fenestrated stent grafts (PMSGs) are a useful option for urgent or semiurgent treatment of complex abdominal aortic aneurysms (CAAAs). The aim of this study was to describe in-hospital outcomes of custom-made fenestrated stent grafts (CMSGs) and PMSGs for the treatment of CAAAs and thoracoabdominal aortic aneurysms (TAAAs).

Methods: In this single-center, retrospective study, all consecutives patients with CAAAs or TAAAs undergoing endovascular repair using Zenith CMSGs (Cook Medical, Bloomington, Ind) or PMSGs between January 2012 and November 2017 were included. End points were intraoperative adverse events, in-hospital mortality, postoperative complications, reinterventions, target vessel patency, and endoleaks.

Results: Ninety-seven patients were included (CMSGs, n = 69; PMSGs, n = 28). The PMSG group included more patients assigned to American Society of Anesthesiologists class 4 (n = 14 [50%] vs n = 16 [23%]; P = .006) and more TAAAs (n = 17 [61%] vs n = 10 [15%]; P < .0001). Intraoperative adverse events were recorded in eight (11%) patients in the CMSG group vs six (21%) patients in the PMSG group. No intraoperative death or open conversion occurred. In-hospital mortality rates were of 4% (n = 3) in the CMSG group and 14% in the PMSG group (n = 4). Chronic renal failure was an independent preoperative risk factor of postoperative death or complications (odds ratio, 4.88; 95% confidence interval, 1.65-14.43; P = .004). Rates of postoperative complications were 22% (n = 15) and 25% (n = 7) in the CMSG and PMSG groups. Spinal cord ischemia rates were 4% (n = 3) and 7% (n = 2) in the CMSG and PMSG groups. Reintervention rates were 16% (n = 11) in the CMSG group and 32% (n = 9) in the PMSG group. At discharge, target vessel patency rate in CMSGs was 98% (n = 207/210). All target vessels (n = 98) were patent in the PMSG group. Endoleaks at discharge were observed in 24% of the CMSG group (n = 16) vs 8% of the PMSG group (n = 2).

Conclusions: Our study showed clinically relevant differences of several important in-hospital outcomes in the CMSG and PMSG groups. Larger cohorts and longer follow-up are needed to allow direct comparison. PMSGs may offer acceptable in-hospital results in patients requiring urgent interventions when CMSGs are not available or possible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7126501PMC
http://dx.doi.org/10.1016/j.jvs.2019.07.102DOI Listing

Publication Analysis

Top Keywords

pmsg group
24
n =
17
stent grafts
16
cmsg group
16
n = cmsg
16
intraoperative adverse
12
adverse events
12
fenestrated stent
12
aortic aneurysms
12
n = pmsg
12

Similar Publications

Modified fenestrated/branched endovascular aortic repair with short bridging stent to treat complex aortic dissection.

Front Cardiovasc Med

November 2024

Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.

Objectives: This study aims to improve fenestrated/branched endovascular aortic repair (F/B EVAR) through fabricating physician-modified stent grafts (PMSG) with short bridging stent to treat complex aortic dissection.

Methods: From November 2018 to January 2024, a total of 82 aortic dissection patients were treated by F/B EVAR combined with short bridging stents, including 19 aortic arch dissection patients and 63 thoracoabdominal aortic dissection patients. Inner or outer short bridging stents were applied to fabricate PMSG with the help of 3D-printing models intraoperatively.

View Article and Find Full Text PDF

Evaluation of Synthetic GnRH-Analog Peforelin with Regard to Oocyte Differentiation and Follicular Development in C57BL/6J Mice.

Animals (Basel)

October 2024

Biomedical Center, Core Facility Animal Models, Faculty of Medicine, Ludwig-Maximilians-Universität München, Großhaderner Straße 9, 82152 Planegg-Martinsried, Germany.

In biomedical research, ovulation induction is a critical step in the reproductive biology of laboratory animals. This study evaluates the efficacy of peforelin, a synthetic gonadotropin-releasing hormone (GnRH) analog, in comparison to pregnant mare serum gonadotropin (PMSG, synonym: eCG), traditionally used for ovulation induction in mice. PMSG is derived from the serum of pregnant horses, and its production is becoming increasingly problematic due to animal welfare concerns and regulatory restrictions.

View Article and Find Full Text PDF

The use of a recombinant equine chorionic gonadotropin (reCG) in fixed-time AI programs in beef cattle.

Theriogenology

October 2024

Instituto de Reproducción Animal Córdoba (IRAC), Córdoba, Argentina; Instituto A.P. de Ciencias Básicas y Aplicadas, Medicina Veterinaria, Universidad Nacional de Villa María, Villa del Rosario, Córdoba, Argentina. Electronic address:

The aim of the current study was to evaluate the effect of a novel recombinant eCG (reCG) on pregnancy rates to AI (P/AI) in suckled beef cows of different breeds that were synchronized with an estradiol/progesterone (P4)-based protocol for fixed-time AI (TAI). In experiment 1, 1244 Bos taurus suckled cows were used. On Day 0 all cows received an intravaginal P4 device (600 mg P4) and 2 mg of estradiol benzoate.

View Article and Find Full Text PDF

Objectives: To observe the effect of electroacupuncture (EA) pre-conditioning on the expression rhythm of clock gene Bmal1 in the uterine tissue of rats with controlled ovarian hyperstimulation(COH), so as to explore its mechanisms underlying improvement of the endometrial receptivity of ovarian superovulation during implantation.

Methods: Seventy-two female SD rats with typical estrous cycles were randomly divided into normal control, model and EA pre-conditioning (pre-EA) groups, with 24 rats in each group. The COH model was established by giving the rats with pregnant mare serum gonadotropin (PMSG) and human chorionic gonadotropin (HCG) by intraperitoneal injection.

View Article and Find Full Text PDF

: Three-dimensional (3D) printing is becoming increasingly popular around the world not only in engineering but also in the medical industry. This trend is visible, especially in aortic modeling for both training and treatment purposes. As a result of advancements in 3D technology, patients can be offered personalized treatment of aortic lesions via physician-modified stent grafts (PMSG), which can be tailored to the specific vascular conditions of the patient.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!