Outcomes during and after the use of the wearable cardioverter-defibrillator in a tertiary-care and a regional hospital in Switzerland.

Swiss Med Wkly

Department of Cardiology, University Hospital of Zurich, Switzerland/ Centre for Integrative Human Physiology, University of Zurich, Switzerland.

Published: November 2019

Introduction: The wearable cardioverter-defibrillator (WCD) has established itself in treatment of potentially life-threatening ventricular arrhythmias, when implantation of an implantable cardioverter-defibrillator (ICD) is not warranted. Careful patient selection for this therapy is crucial, but unfortunately very little information from randomised controlled trials is available to guide clinical decision-making. Consequently, data from real-world patient registries play a more important role in this context.

Materials And Methods: A retrospective observational study was conducted at the University Hospital of Zurich and the GZO Regional Healthcare Centre in Wetzikon. Clinical databases were screened for patients with a history of WCD use from the time of its approval in Switzerland in July 2014 until February 2018. Baseline characteristics, WCD data and outcome data, with an emphasis on ICD implantation and ICD therapies, were collected and analysed.

Results: Two-hundred and seven patients were included in the primary analysis. Eighty-six percent were male and the mean age was 58 ± 13 years. The underlying heart disease was ischaemic cardiomyopathy (ICM), non-ischaemic cardiomyopathy (NICM) and congenital/inherited heart diseases in 60, 35 and 5%, respectively. The most common indication for WCD use was heart failure with an ejection fraction (EF) <35% due to ICM or NICM (43 and 27%, respectively). Three of the 207 patients received an appropriate shock over a median WCD wear-time of 62 days (interquartile range [IQR] 35–95). No inappropriate shocks were registered. Median average daily wear-time was 22.6 hours (IQR 19.9–23.2) and was significantly shorter for patients for whom WCD discontinuation was due to comfort issues (17 patients, p = 0.003). After the end of WCD therapy, 48% were implanted with an ICD. In those receiving an ICD, the rate of appropriate ICD therapies (either shock or antitachycardia pacing) was 8% during a median follow-up of 110 days (IQR 23–421).

Conclusion: The WCD is safe and effective in terminating malignant ventricular arrhythmias. A substantial subgroup of patients, however, discontinued WCD use prematurely because of comfort issues. This subset of patients deserves further attention in clinical practice to ensure therapy adherence.  .

Download full-text PDF

Source
http://dx.doi.org/10.4414/smw.2019.20136DOI Listing

Publication Analysis

Top Keywords

wcd
9
wearable cardioverter-defibrillator
8
ventricular arrhythmias
8
icd therapies
8
comfort issues
8
patients
7
icd
6
outcomes wearable
4
cardioverter-defibrillator tertiary-care
4
tertiary-care regional
4

Similar Publications

Background: A wearable cardioverter defibrillator (WCD) is indicated for a limited period in patients at high risk of sudden cardiac death (SCD). Nonischemic heart failure (HF) is common among Japanese patients with HF. The aim of this study was to evaluate the incidence of fatal arrhythmias during WCD use and the clinical outcomes after WCD withdrawal in Japanese patients with HF.

View Article and Find Full Text PDF

Association of BMI with adherence and outcome in heart failure patients treated with wearable cardioverter defibrillator.

ESC Heart Fail

October 2024

Department of Cardiology, Angiology, Haemostaseology and Medical Intensive Care, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany.

Article Synopsis
  • - The study investigates the relationship between obesity and heart failure in patients using a wearable cardioverter-defibrillator, finding that those with a BMI over 30 kg/m^2 had better left ventricular ejection fraction improvements than patients with lower BMIs.
  • - Despite similar adherence to using the defibrillator and rates of arrhythmic events across different BMI groups, patients with a BMI over 30 experienced significantly lower rehospitalization rates for cardiovascular issues compared to those with a BMI between 25-30.
  • - At a two-year follow-up, mortality rates were notably lower for the highest BMI group (5.9%) compared to those with a BMI under 25 (7.5%), highlighting a potential 'ob
View Article and Find Full Text PDF
Article Synopsis
  • Wearable cardioverter-defibrillators (WCD) are non-invasive devices designed for patients at risk of life-threatening arrhythmias, providing continuous monitoring and the ability to deliver prompt defibrillation when necessary.
  • The study involved 41 patients monitored from November 2022 to May 2024, focusing on tailored therapy through regular check-ups and remote monitoring, with a significant portion of patients experiencing conditions like hypertension and heart failure.
  • Results showed that the majority of patients did not require further device interventions; only 29% ultimately needed an implantable cardioverter-defibrillator (ICD), suggesting that WCD use can help optimize treatment decisions and reduce unnecessary ICD implants.
View Article and Find Full Text PDF

Background And Objective: The healthcare-seeking behavior of vulnerable groups, such as children under five, depends on a multitude of factors, including the caregiver's decision making. Approximately 60% of Indians seek care from private hospitals. Recent health policy in India has favored the establishment of multispecialty hospitals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!