Objectives: To evaluate the feasibility and outcomes of cochlear implantation (CI) in infancy.

Methods: All infants who underwent CI from January 2011 to October 2018 at a tertiary referral center in the Kingdom of Saudi Arabia were retrospectively reviewed. Demographic data, factors associated with early detection, and any surgical difficulties or postoperative complications were extracted from the medical records. The outcome of CI was determined by a speech pathologist.

Results: Fifteen patients underwent CI during the study period (9 bilateral and performed simultaneously, 6 unilateral). The round window was difficult to identify in 5 cases. Incomplete electrode insertion because of cochlear ossification secondary to meningitis was documented in one patient. No major postoperative complications were encountered. The average auditory performance score was 7 and the speech intelligibility rating was 5.

Conclusions: This study represents the largest national cohort of pediatric patients undergoing CI in infancy. In this series, the surgery was safe and the speech outcome was good. With implementation of the neonatal screening program in the Kingdom of Saudi Arabia, the number of infants undergoing CI is likely to increase in the near future, paving the way for more research in infant CI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6901779PMC
http://dx.doi.org/10.15537/smj.2019.11.24061DOI Listing

Publication Analysis

Top Keywords

cochlear implantation
8
kingdom saudi
8
saudi arabia
8
postoperative complications
8
surgical considerations
4
speech
4
considerations speech
4
speech outcomes
4
outcomes infants
4
infants undergo
4

Similar Publications

Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness: A Randomized Clinical Trial.

JAMA Otolaryngol Head Neck Surg

January 2025

Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.

Importance: There is a lack of high level of evidence studies comparing the effect of different treatment options for single-sided deafness (SSD).

Objective: To determine the effect of a cochlear implant (CI), bone conduction device (BCD), contralateral routing of signals hearing aid (CROS), and no treatment on speech perception in noise outcomes in patients with SSD.

Design, Setting, And Participants: In this single-center randomized clinical trial, adult patients with SSD were randomized into 3 groups: CI; a trial period with first a BCD on a headband and then a CROS; or a trial period with first a CROS and then a BCD on a headband.

View Article and Find Full Text PDF

When listening to speech under adverse conditions, listeners compensate using neurocognitive resources. A clinically relevant form of adverse listening is listening through a cochlear implant (CI), which provides a spectrally degraded signal. CI listening is often simulated through noise-vocoding.

View Article and Find Full Text PDF

Background: Pediatric cochlear implant (CI) recipients with cochlear malformations face challenges due to variable speech recognition outcomes.

Aims/objectives: This study assesses the predictive value of intraoperative electrically evoked compound action potential (eCAP) thresholds, residual hearing, age at implantation, Intelligent Quotient (IQ), and malformation type for speech recognition outcomes.

Material And Methods: A prospective cohort of 52 children (aged 1-4 years) with cochlear malformations who underwent CI between 2016 and 2024 was analyzed.

View Article and Find Full Text PDF

Former studies have established that individuals with a cochlear implant (CI) for treating single-sided deafness experience improved speech processing after implantation. However, it is not clear how each ear contributes separately to improve speech perception over time at the behavioural and neural level. In this longitudinal EEG study with four different time points, we measured neural activity in response to various temporally and spectrally degraded spoken words presented monaurally to the CI and non-CI ears (5 left and 5 right ears) in 10 single-sided CI users and 10 age- and sex-matched individuals with normal hearing.

View Article and Find Full Text PDF

Objectives: This study was designed to (1) compare preactivation and postactivation performance with a cochlear implant for children with functional preoperative low-frequency hearing, (2) compare outcomes of electric-acoustic stimulation (EAS) versus electric-only stimulation (ES) for children with versus without hearing preservation to understand the benefits of low-frequency acoustic cues, and (3) to investigate the relationship between postoperative acoustic hearing thresholds and performance.

Design: This was a prospective, 12-month between-subjects trial including 24 pediatric cochlear implant recipients with preoperative low-frequency functional hearing. Participant ages ranged from 5 to 17 years old.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!