Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The reported methods for the estimation of CG are indirect, long and tedious uses solvent extraction which results in lower recoveries due to several co-eluted components. The present study aims to develop and validate a high throughput method for the analysis of cyanogenic glycosides (CG) in flaxseed using extractive silylation. The experimental procedure comprised of preparation of trimethylsilyl (TMS) derivatives of CG, their quantitation through gas chromatography with flame ionization detector (GC-FID) and further characterization by LC-MS/MS. Different validation parameters determined in the experiment include the relative standard deviation both inter-day and intraday less than 5%, recovery in the range of 79.9-112.7%, limit of detection 4.72-6.43 µg/mL and limit of quantitation 14.31-19.50 µg/mL. Combinations of silylation reagent were screened in a central composite experimental design in order to examine their effect on the extraction recovery. Finally, the developed method was applied successfully to quantify CG in various flaxseed cultivars. Advantages of the extractive silylation are simple preparation, short reaction times and the combination of extraction and silylation in one step which indicate that the method has the potential to sensitively and accurately determine CG where large numbers of samples are being routinely analysed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2019.121816 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!