The pulse arrival time (PAT), pre-ejection period (PEP) and pulse transit time (PTT) are calculated using on-body continuous wave radar (CWR), Photoplethysmogram (PPG) and Electrocardiogram (ECG) sensors for wearable continuous systolic blood pressure (SBP) measurements. The CWR and PPG sensors are placed on the sternum and left earlobe respectively. This paper presents a signal processing method based on wavelet transform and adaptive filtering to remove noise from CWR signals. Experimental data are collected from 43 subjects in various static postures and 26 subjects doing 6 different exercise tasks. Two mathematical models are used to calculate SBPs from PTTs/PATs. For 38 subjects participating in posture tasks, the best cumulative error percentage (CEP) is 92.28% and for 21 subjects participating in exercise tasks, the best CEP is 82.61%. The results show the proposed method is promising in estimating SBP using PTT. Additionally, removing PEP from PAT leads to improving results by around 9%. The CWR sensors present a low-power, continuous and potentially wearable system with minimal body contact to monitor aortic valve mechanical activities directly. Results of this study, of wearable radar sensors, demonstrate the potential superiority of CWR-based PEP extraction for various medical monitoring applications, including BP measurement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6841972PMC
http://dx.doi.org/10.1038/s41598-019-52710-8DOI Listing

Publication Analysis

Top Keywords

blood pressure
8
on-body continuous
8
continuous wave
8
wave radar
8
exercise tasks
8
subjects participating
8
tasks best
8
pressure estimation
4
estimation on-body
4
continuous
4

Similar Publications

Arterial hypertension in young adults, which includes patients between 19 and 40 years of age, has been increasing in recent years and is associated with a significantly higher risk of target organ damage and short-term mortality. It has been reported that up to 10% of these cases are due to a potentially reversible secondary cause, mainly of endocrine (primary aldosteronism, Cushing's syndrome, and pheochromocytoma/paraganglioma), renal (renovascular hypertension due to fibromuscular dysplasia and renal parenchymal disease), or cardiac (coarctation of the aorta) origin. It is recommended to rule out a secondary cause of high blood pressure (BP) in those patients with early onset of grade 2 or 3 hypertension, acute worsening of previously controlled hypertension, resistant hypertension, hypertensive emergency, severe target organ damage disproportionate to the grade of hypertension, or in the face of clinical or biochemical characteristics suggestive of a secondary cause of hypertension.

View Article and Find Full Text PDF

Objectives: The primary aim of this study was to evaluate the effects of vasodilator administration on CT angiography (CTA) prostatic artery diameter and peak opacification in dogs with prostatic carcinoma prior to prostatic artery embolization (PAE).

Materials And Methods: A prospective clinical trial was performed. Ten dogs with naturally occurring prostatic carcinoma and no evidence of cardiovascular disease were enrolled.

View Article and Find Full Text PDF

Background: Metabolic syndrome (met-s) is a medical condition that includes abdominal obesity, hyperlipidemia, high blood glucose, and high blood pressure. It is associated with a high risk of developing cardiovascular diseases and type 2 diabetes mellitus. The condition was believed to be a challenge mostly faced by developed nations.

View Article and Find Full Text PDF

BACKGROUND Appropriate management of patients who have fallen is crucial for reducing damage and mortality. We report the case of a patient who fell from a seated position, which caused traumatic liver injury, with gastrointestinal symptoms as the primary patient concern. CASE REPORT A woman in her 80s who was living independently fell from a seated position during the daytime.

View Article and Find Full Text PDF

Arterial hypertension and increased atherogenic index of plasma (AIP) are strong predictors of cardiovascular risk associated in individuals with obesity both in adults and children. Thus, we aimed to explore the relationship between AIP and systolic ambulatory blood pressure index (sABPI) with left ventricular geometry pattern in obese children. In this cross-sectional study, a total of 129 obese children (BMI greater or equal to the 95th percentile for age and sex) were examined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!