Topography and pachymetry maps for mouse corneas using optical coherence tomography.

Exp Eye Res

Ophthalmology, Duke University, Durham, NC, USA; Biomedical Engineering, Duke University, Durham, NC, USA. Electronic address:

Published: January 2020

The majority of the eye's refractive power lies in the cornea, and pathological changes in its shape can affect vision. Small animal models offer an unparalleled degree of control over genetic and environmental factors that can help elucidate mechanisms of diseases affecting corneal shape. However, there is not currently a method to characterize the corneal shape of small animal eyes with topography or pachymetry maps, as is done clinically for humans. We bridge this gap by demonstrating methods using optical coherence tomography (OCT) to generate the first topography and pachymetry (thickness) maps of mouse corneas. Radii of curvature acquired using OCT were validated using calibration spheres as well as in vivo mouse corneas with a mouse keratometer. The resulting topography and pachymetry maps are analogous to those used diagnostically in clinic and potentially allow for characterization of genetically modified mice that replicate key features of human corneal disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6961820PMC
http://dx.doi.org/10.1016/j.exer.2019.107868DOI Listing

Publication Analysis

Top Keywords

topography pachymetry
16
pachymetry maps
12
mouse corneas
12
maps mouse
8
optical coherence
8
coherence tomography
8
small animal
8
corneal shape
8
topography
4
maps
4

Similar Publications

Purpose: To evaluate the clinical outcomes of implanting two symmetrical Kerarings via a femtosecond laser in grade three keratoconus.

Patients And Methods: This was a retrospective nonrandomized controlled clinical study. The study included one eye from each of twenty-three patients, all with Grade 3 keratoconus as classified by the Amsler-Krumeich classification.

View Article and Find Full Text PDF

Purpose: To assess the safety and the efficacy of the "Sub-400 corneal cross-linking (CXL) protocol" for progressive keratoconus (KC) in ultrathin corneas.

Methods: The study included thirty four patients with progressive KC, who underwent CXL using the "Sub-400" protocol due to intraoperative thinnest corneal pachymetry ranging from 295 to 398 μm after epithelial removal. After the epithelium was removed, the following ultraviolet A irradiation was applied at a fluence of 3 mW/cm and the duration was adjusted based on the specific corneal stromal thickness.

View Article and Find Full Text PDF

To report a novel application within the USA of excimer ablation for the normalization of central corneal refractive irregularity, combined with higher fluence CXL in the effective management and visual rehabilitation of progressive keratoconus. 17 consecutive cases with progressive keratoconus were treated with corneal surface excimer laser ablation normalization using topography-guided (Contura) myopic ablation for customized corneal re-shaping with a 6 mm optical zone. The epithelial removal was accounted for by adding a -2.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of eyelid laxity on the structure of the cornea.

Methods: This was a retrospective study performed in one institution. Patients with and without upper and lower eyelid laxity, which were determined using the snap-back test (SBT) and the upper eyelid distraction test (LDT), were evaluated for corneal structural changes with Scheimpflug imaging corneal tomography for the keratometric readings, and cor-neal spectral domain optical coherence tomography for the epithelial thickness (ET) measurements.

View Article and Find Full Text PDF

Purpose: To compare and assess the visual, refractive, and tomographic results of patients with corneal ectasia treated with either corneal allogenic intrastromal ring segments (CAIRS) or synthetic intrastromal corneal ring segments (ICRS) without concomitant corneal cross-linking.

Methods: In this retrospective cohort study, 34 eyes with CAIRS were matched to 34 eyes with ICRS using the propensity score matching technique. Each group was matched on a oneto-one basis using multiple parameters such as central corneal thickness, vertical and horizontal coma, maximum anterior keratometry, steepest keratometry, and age.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!