A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical performance of titanium-zirconium implants with a hydrophilic surface in patients with controlled type 2 diabetes mellitus: 2-year results from a prospective case-control clinical study. | LitMetric

Objective: Analyze the 2-year clinical performance of single-unit titanium-zirconium (TiZr) alloy narrow-diameter (3.3 mm) dental implants with a hydrophilic surface (Straumann® Roxolid®, SLActive®) in patients with controlled type 2 diabetes mellitus (T2DM), measured using the glycated hemoglobin A (HbA1c) concentration test, compared with results in individuals without T2DM.

Material And Methods: The studied sample consisted of 28 patients, 14 with T2DM (study group) and 14 without (control group). The plaque index, bleeding on probing, probing depth, clinical attachment level, gingival biotype, and marginal bone loss (MBL) at the site of the implants were assessed. HbA1c levels were assessed in all patients during each checkup.

Results: Two years after implant placement and prosthetic restoration no implant failures were reported in either group, resulting in 100% survival and success rates in both groups. No statistically significant differences in MBL were found between the control and study groups (p > 0.05).

Conclusions: Within the limitations of this study, it can be concluded that reduced-diameter TiZr alloy implants with a hydrophilic surface represent a safe and predictable treatment option for patients with well-controlled T2DM. The clinical performance was comparable with that observed in individuals without T2DM in the medium term.

Clinical Relevance: The narrow implants placed in patients with T2DM with well-controlled glycemia (HbA1c) showed a marginal bone loss and success and survival rates similar to those of the control group without DM2, in the medium term.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-019-03110-9DOI Listing

Publication Analysis

Top Keywords

clinical performance
12
implants hydrophilic
12
hydrophilic surface
12
patients controlled
8
controlled type
8
type diabetes
8
diabetes mellitus
8
tizr alloy
8
patients t2dm
8
control group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!