Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Transcatheter aortic valve implantation (TAVI) is currently becoming an alternative to surgical valve replacement for patients at low risk, a population that is likely to experience an increase in the radiation-induced cancer risk following TAVI. We aimed to evaluate the overall exposure to ionizing radiation in patients who underwent transfemoral TAVI, including the procedure itself as well as the procedures performed in the preintervention work-up and the post-TAVI interventions. All patients who underwent transfemoral TAVI for symptomatic aortic stenosis in our center over a 26 months period were included. Dosimetric indicators from preprocedural coronary angiography and computed tomography (CT), the TAVI procedure, and any postprocedural interventions (electrophysiology study and/or pacemaker implantation) were collected and converted into an effective dose. A total of 119 transfemoral TAVI procedures were included. The mean cumulative effective dose (ED) was 37.3 mSv. Three irradiating procedures were necessary for 84 patients (71% of the population, i.e., coronary angiography, CT scan and the TAVI procedure itself), whereas 30 patients (25%) required a fourth procedure, and 5 required a fifth (4%). The majority of the dose was from the CT, while only 11% of the dose derived from the TAVI procedure itself. In conclusion, overall exposure to ionizing radiation for patients who underwent transfemoral TAVI seems acceptable, and the majority of the overall ED comes from the CT scan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2019.09.028 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!