The Eversense Continuous Glucose Monitoring (CGM) System, with the first long-term, implantable glucose sensor, has been commercially available in Europe and South Africa since 2016 for adults with diabetes. The performance of the sensor over multiple, sequential 90- or 180-day cycles from either real-world experience or clinical studies has not been previously published. The Eversense Data Management System (DMS) was used to evaluate the accuracy of General Data Protection Regulation (GDPR)-compliant sensor glucose (SG) values against self-monitoring of blood glucose (SMBG) from June 2016 through August 2019 among patients with at least four sensor cycles from European and South African health care practices. Mean SG and associated measures of variability, glucose management indicator (GMI), and percent and time in various hypoglycemic, euglycemic, and hyperglycemic ranges were calculated for the 24-h time period over each cycle. In addition, transmitter wear time was evaluated across each sensor wear cycle. Among the 945 users included in the analysis, the mean absolute relative difference (standard deviation [SD]) using 152,206, 174,645, 206,024, and 172,587 calibration matched pairs against SMBG was 11.9% (3.6%), 11.5% (4.0%), 11.8% (4.7%), and 11.5% (4.1%) during the first four sensor cycles, respectively. Mean values of the CGM metrics over the first sensor cycle were 156.5 mg/dL for SG, 54.7 mg/dL for SD, 0.35 for coefficient of variation, and 7.04% for GMI. Percent SG at different glycemic ranges was as follows: <54 mg/dL was 1.1% (16 min), <70 mg/dL was 4.6% (66 min), ≥70-180 mg/dL (time in range) was 64.5% (929 min), >180-250 mg/dL was 22.8% (328 min), and >250 mg/dL was 8.1% (117 min). The median transmitter wear time over the first cycle was 83.2%. CGM metrics and wear time were similar over the subsequent three cycles. This real-world evaluation of adult patients with diabetes using the Eversense CGM System in the home setting demonstrated that the implantable sensor provides consistent stable accuracy and CGM metrics over multiple, sequential sensor cycles with no indication of degradation of sensor performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196365PMC
http://dx.doi.org/10.1089/dia.2019.0342DOI Listing

Publication Analysis

Top Keywords

sensor
12
sensor cycles
12
wear time
12
cgm metrics
12
continuous glucose
8
glucose sensor
8
sensor multiple
8
cgm system
8
multiple sequential
8
cycles real-world
8

Similar Publications

The next generation of stretchable electronics seeks to integrate superior mechanical properties with sustainability and sensing stability. Ionically conductive and liquid-free elastomers have gained recognition as promising candidates, addressing the challenges of evaporation and leakage in gel-based conductors. In this study, a sustainable polymeric deep eutectic system is synergistically integrated with amino-terminated hyperbranched polyamide-modified fibers and aluminum ions, forming a conductive supramolecular network with significant improvements in mechanical performance.

View Article and Find Full Text PDF

This study addresses the significant issue of rapid land use and land cover (LULC) changes in Lahore District, which is critical for supporting ecological management and sustainable land-use planning. Understanding these changes is crucial for mitigating adverse environmental impacts and promoting sustainable development. The main goal is to evaluate historical LULC changes from 1994 to 2024 and forecast future trends for 2034 and 2044 utilizing the CA-Markov hybrid model combined with GIS methodologies.

View Article and Find Full Text PDF

Measurement and Assessment of Head-to-Helmet Contact Forces.

Ann Biomed Eng

January 2025

Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.

Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.

Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.

View Article and Find Full Text PDF

A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites.

View Article and Find Full Text PDF

Mechanical ventilation is the process through which breathing support is provided to patients who face inconvenience during respiration. During the pandemic, many people were suffering from lung disorders, which elevated the demand for mechanical ventilators. The handling of mechanical ventilators is to be done under the assistance of trained professionals and demands the selection of ideal parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!