Purpose: Diméglio (DimS) and Pirani (PirS) scores are the most commonly used scoring systems for evaluation of clubfoot, with many centres performing both. Interobserver reliability of their global score has been rated high in a few studies, but agreement of their subcomponents has been poorly investigated. The aim of the study was to assess interrater reliability of global scores and of items in a clinical setting and to analyse overlapping features of the two scores.
Methods: Fifty-six consecutive idiopathic clubfeet undergoing correction using the Ponseti method were independently evaluated at each casting session by two trained paediatric orthopaedic surgeons using both scores. Interobserver reliability of collected data was analysed; a kappa coefficient > 0.60 was considered adequate.
Results: For DimS and PirS, the Pearson correlation coefficients were 0.87 and 0.91 (p < .0001) respectively, and kappa coefficients were 0.23 and 0.31. Among subcomponents, kappa values were rated > 0.60 only for equinus and curvature of lateral border in PirS; muscular abnormality in DimS was rated 0.74 but a high prevalence index (0.94) indicated influence of scarce prevalence of this feature. All other items showed k < 0.60 and were considered to be improved.For overlapping features: posterior and medial crease showed similar agreement in the two systems, items describing equinus and midfoot adduction were much more reliable in PirS than in DimS.
Conclusions: In a clinical setting, despite a high correlation of evaluations for total scores, the interobserver agreement of DimS and PirS was not adequate and only a few items were substantially reliable. Simultaneous use of two scores seemed redundant and some overlapping features showed different reliability according to criterion or scale used. Future scoring systems should improve these limitations.
Level Of Evidence: Level I - Diagnostic studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6808069 | PMC |
http://dx.doi.org/10.1302/1863-2548.13.190010 | DOI Listing |
J Magn Reson Imaging
February 2025
BioMedical Engineering and Imaging Institute, Icahn School of Medicine Mount Sinai, New York, New York, USA.
Background: Several factors can impair image quality and reliability of liver magnetic resonance elastography (MRE), such as inadequate driver positioning, insufficient wave propagation and patient-related factors.
Purpose: To report initial results on automatic classification of liver MRE image quality using various deep learning (DL) architectures.
Study Type: Retrospective, single center, IRB-approved human study.
The diagnostic workup of primary lymphedema includes lymphoscintigraphy, a diagnostic test that provides objective data derived from the characteristics of the lymphatic flow and the lymphatic nodes. Several empirical scoring systems have been proposed with the aim of harmonizing the procedure. Here we comment the latest one, reflecting on the relevance of these tools to make possible multicenter research, based on intraobserver and interobserver reliability with the aim to, in the long run, improve patient outcomes.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-minamimachi, Chuo-ku, Kobe, 650-0047, Japan.
Background: Although the Neer and AO/OTA classifications have been widely accepted, observer reliability studies of these two classifications have questioned their reliability and reproducibility to date. We developed an entirely new classification, the Mitsuzawa classification, for dislocated and displaced proximal humeral fractures and tested all three classifications for their intra- and interobserver reliability.
Methods: Two experienced shoulder surgeons and two orthopedic residents independently evaluated the Xray (xR) values of 100 proximal humeral fractures (PHFs).
Medicina (Kaunas)
December 2024
Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.
: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.
View Article and Find Full Text PDFBiomedicines
November 2024
Clinic for Trauma and Reconstructive Surgery, University Hospital Heidelberg, 69118 Heidelberg, Germany.
: The elbow joint is stabilized by complex interactions between bony structures and soft tissues, notably the lateral and medial collateral ligaments. Posterolateral rotatory instability (PLRI), a form of elbow instability, is challenging to diagnose due to overlapping symptoms with other conditions. The radiocapitellar line (RCL) is a radiographic tool for assessing humeroradial alignment and elbow stability, but its diagnostic accuracy remains debated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!