Adverse reaction to titanium-based breast marker clip is a very uncommon complication in medicine. We report a 65-year-old female patient who was referred with left breast lumpiness to the assessment clinic. Breast radiology with interesting sequelae following titanium clip insertion, in combination with literature review, will be discussed. The patient had a history of adverse skin reactions to base metals. However, no allergy specifically to titanium was reported. Imaging findings with regard to the symptomatic breast were nonspecific; thus, multiple core biopsies were taken, and titanium clip was inserted. Subsequent histological examination showed benign changes. However, 7 weeks later, the marked area became very tender and the same patient re-presented to the clinic, requesting removal of the metallic component. Following multidisciplinary meetings and discussions, the person underwent ultrasound-guided vacuum biopsy and the clip was removed. The symptoms completely resolved after the successful procedure, and histological examination revealed lymphocytic infiltration of the tissues. Reactions to titanium-based marker clips are rare and only limited records have been found in the literature. More cases need to be reported in order to establish the full significance of such adverse sequelae. It is recommended that medical history with regard to allergies, prior titanium clip insertions, should be discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6718166PMC
http://dx.doi.org/10.2147/IMCRJ.S222484DOI Listing

Publication Analysis

Top Keywords

titanium clip
12
adverse reaction
8
reaction titanium-based
8
titanium-based marker
8
marker clip
8
histological examination
8
clip
6
adverse
4
clip case
4
case report
4

Similar Publications

: Postoperative cerebrospinal fluid (CSF) fistulas remain a significant concern in spinal neurosurgery, particularly following dural closure. The incidence of dural tears during spinal surgery is estimated between 1.6% and 10%.

View Article and Find Full Text PDF

Introduction: Preventing staple line bleeding (SLB) is still a main issue in bariatric surgery procedures, especially after laparoscopic sleeve gastrectomy (LSG). Staple line reinforcements (SLR), mattress sutures, or titanium clip application did not show any statistical superiority compared to other methods. In this randomized controlled trial, we tested hemostatic powder (HP) in order to assess a possible role in the prevention of active bleeding, hematoma formation, the need for transfusions, and the increased risk for hospitalization.

View Article and Find Full Text PDF

Introduction And Importance: There are few cases of multiple simultaneous anterior communicating artery (AComA) aneurysms with A2 triplication and AComA duplication.

Cases Presentation: (1) A fenestrated AComA with a saccular aneurysm (neck diameter 9 mm; dome height 8 mm) projecting superiorly from the distal AComA branch, as well as an anomalous artery arising from the posterior surface of the same AComA. (2) A duplicate AComA with a saccular aneurysm (neck diameter of 5 mm; dome height of 9 mm) projecting superioposteriorly from the distal AComA branch, as well as an anomalous artery arising from the anterior surface of the same AComA was diagnosed.

View Article and Find Full Text PDF

Large vestibular aqueduct syndrome (LVAS) is a congenital malformation characterized by an abnormally large vestibular aqueduct, diagnosed primarily via CT scans. Patients with LVAS often experience progressive hearing loss and recurrent vertigo, with treatment strategies mirroring those for Meniere's disease. Traditional surgical interventions such as endolymphatic sac decompression (ESD) are common; however, the efficacy of endolymphatic duct blockage (EDB) as an alternative still remains under investigation.

View Article and Find Full Text PDF

[Influence of operator's experience on the quality and success rate of root canal treatment with new nickel-titanium instruments].

Zhonghua Kou Qiang Yi Xue Za Zhi

November 2024

Center for Microscope Enhanced Dentistry, School of Stomatology, Capital Medical University, Beijing100162, China.

Article Synopsis
  • The study evaluates how the experience level of operators affects the quality and success of root canal treatments using new nickel-titanium instruments, highlighting the need for improvement in clinical practices.
  • Data was collected from 277 cases performed by residents (1-3 years of experience) and specialists (5-7 years of experience), comparing complication rates, filling quality, and overall success rates.
  • Results showed that residents had a higher incidence of flare-ups and lower rates of satisfactory fillings compared to specialists, but both groups had similar overall success rates, suggesting that operator experience significantly influences treatment quality but not necessarily the ultimate success of the procedure.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!