The interest in generating "synthetic computed tomography (CT) images" from magnetic resonance (MR) images has been increasing over the past years due to advances in MR guidance for radiotherapy. A variety of methods for synthetic CT creation have been developed, from simple bulk density assignment to complex machine learning algorithms. In this study, we present a general method to determine simplistic synthetic CTs and evaluate them according to their dosimetric accuracy. It separates the requirements on the MR image and the associated calculation effort to generate a synthetic CT. To evaluate the significance of the dosimetric accuracy under realistic conditions, clinically common uncertainties including position shifts and Hounsfield lookup table (HLUT) errors were simulated. To illustrate our approach, we first translated CT images from a test set of six pelvic cancer patients to relative electron density (ED) via a clinical HLUT. For each patient, seven simplified ED images (simED) were generated at different levels of complexity, ranging from one to four tissue classes. Then, dose distributions optimised on the reference ED image and the simEDs were compared to each other in terms of gamma pass rates (2 mm/2% criteria) and dose volume metrics. For our test set, best results were obtained for simEDs with four tissue classes representing fat, soft tissue, air, and bone. For this simED, gamma pass rates of 99.95% (range: 99.72-100%) were achieved. The decrease in accuracy from ED simplification was smaller in this case than the influence of the uncertainty scenarios on the reference image, both for gamma pass rates and dose volume metrics. The presented workflow helps to determine the required complexity of synthetic CTs with respect to their dosimetric accuracy. The investigated cases showed potential simplifications, based on which the synthetic CT generation could be faster and more reproducible.

Download full-text PDF

Source
http://dx.doi.org/10.1080/0284186X.2019.1684558DOI Listing

Publication Analysis

Top Keywords

dosimetric accuracy
16
gamma pass
12
pass rates
12
synthetic cts
8
test set
8
tissue classes
8
reference image
8
dose volume
8
volume metrics
8
synthetic
6

Similar Publications

Purpose: Conventional radiotherapy (CRT) has limited local control and poses a high risk of severe toxicity in large lung tumors. This study aimed to develop an integrated treatment plan that combines CRT with lattice boost radiotherapy (LRT) and monitors its dosimetric characteristics.

Methods: This study employed cone-beam computed tomography from 115 lung cancer patients to develop a U-Net +  + deep learning model for generating synthetic CT (sCT).

View Article and Find Full Text PDF

Purpose: We aimed to build a machine learning-based model to predict radiation-induced optic neuropathy in patients who had treated head and neck cancers with radiotherapy.

Materials And Methods: To measure radiation-induced optic neuropathy, the visual evoked potential values were obtained in both case and control groups and compared. Radiomics features were extracted from the area segmented which included the right and left optic nerves and chiasm.

View Article and Find Full Text PDF

Background: Stereotactic body radiation therapy (SBRT) is crucial for treating early-stage inoperable non-small cell lung cancer (NSCLC) due to its precision and high-dose delivery. This study aimed to investigate the dosimetric deviations in gated (GR) versus non-gated radiotherapy (NGR), analyzing the impact of tumor location, target volume, and tumor motion range on dose distribution accuracy.

Methods: Sixty patients treated with either gated (n=30) or non-gated (n=30) SBRT for early-stage NSCLC were retrospectively analyzed.

View Article and Find Full Text PDF

This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.

View Article and Find Full Text PDF

Background: Dosimetric commissioning and quality assurance (QA) for linear accelerators (LINACs) present a significant challenge for clinical physicists due to the high measurement workload and stringent precision standards. This challenge is exacerbated for radiosurgery LINACs because of increased measurement uncertainty and more demanding setup accuracy for small-field beams. Optimizing physicists' effort during beam measurements while ensuring the quality of the measured data is crucial for clinical efficiency and patient safety.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!