Purpose: To evaluate the ability of a novel ultrasound (US) device, DiaMon, to monitor diaphragm movement via its proxy liver movement, and compare it with the respired flow measured with a flowmeter, in awake and healthy volunteers. We wanted to (1) establish the optimal anatomical position for attaching the DiaMon device to the abdominal wall, and (2) evaluate the accuracy of continuous monitoring of respiratory frequency.
Methods: Thirty healthy subjects were recruited. The DiaMon probe was applied subcostally in four different positions with the subjects in five different postures. The subjects breathed tidal volumes into a spirometer for 30-60 s with the DiaMon recording simultaneously.
Results: The device detected a readable signal in 83-100% of the position/posture-combinations. The technical correlation between the two signals was highest in the anterior axillary-supine position (mean ± SD: 0.95 ± 0.03), followed by paramidline-supine (0.90 ± 0.09) and midclavicular-supine (0.89 ± 0.12). The frequency measurements yielded a mean difference of 0.03 (95% limits of agreement - 0.11, 0.16) breaths per minute in the anterior axillary-supine position.
Conclusion: The DiaMon device is able to detect liver movement in most subjects, and it measures breathing frequency accurately.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7925735 | PMC |
http://dx.doi.org/10.1007/s40477-019-00412-2 | DOI Listing |
Diagnostics (Basel)
December 2024
Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy.
Dynamic digital radiography (DDR) is a recent imaging technique that allows for real-time visualization of thoracic and pulmonary movement in synchronization with the breathing cycle, providing useful clinical information. A 46-year-old male, a former smoker, was evaluated for unexplained dyspnea and reduced exercise tolerance. His medical history included a SARS-CoV-2 infection in 2021.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2024
Department of General Thoracic Surgery, Juntendo University School of Medicine, Tokyo, Japan.
Dynamic chest radiography (DCR) is a novel radiographic technique that evaluates the thoracic movement from inspiration to expiration. Here, we report the efficacy of DCR in the surgical treatment of diaphragmatic paralysis. A 60-year-old woman presented with phrenic nerve palsy after anterior mediastinal resection.
View Article and Find Full Text PDFInt J Chron Obstruct Pulmon Dis
January 2025
Pulmonology Department, Erciyes University Faculty of Medicine, Kayseri, Türkiye.
Background/aim: Chronic obstructive pulmonary disease (COPD) is often complicated by sarcopenia, a condition of reduced muscle mass and function that adversely affects quality of life, lung function, and exacerbation rates. Ultrasonography could be an effective tool for detecting sarcopenia, notably by assessing diaphragmatic function, which may indicate muscle health in COPD patients. This study aims to evaluate the effectiveness of diaphragmatic ultrasound in detecting sarcopenia among COPD patients.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.
Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.
Sci Rep
January 2025
Department of Anesthesiology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No.600 Yishan Road, Xuhui District, Shanghai, 200233, People's Republic of China.
Regional anesthesia is a popular method for surgical anesthesia in clavicular surgery. Selective blocking of the cervical 3, 4, and 5 nerve roots shows promise in clavicle surgery, with its fast onset, good anesthesia and less complications, necessitating evaluation of its impact on diaphragmatic function. The purpose of this study is to examine the safety of C3, 4, and 5 nerve root block for its application in clavicle surgery.