ActiveAx : Toward non-parametric and orientationally invariant axon diameter distribution mapping using PGSE.

Magn Reson Med

Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Vaud, Switzerland.

Published: June 2020

Purpose: Non-invasive axon diameter distribution (ADD) mapping using diffusion MRI is an ill-posed problem. Current ADD mapping methods require knowledge of axon orientation before performing the acquisition. Instead, ActiveAx uses a 3D sampling scheme to estimate the orientation from the signal, providing orientationally invariant estimates. The mean diameter is estimated instead of the distribution for the solution to be tractable. Here, we propose an extension (ActiveAx ) that provides non-parametric and orientationally invariant estimates of the whole distribution.

Theory: The accelerated microstructure imaging with convex optimization (AMICO) framework accelerates mean diameter estimation using a linear formulation combined with Tikhonov regularization to stabilize the solution. Here, we implement a new formulation (ActiveAx ) that uses Laplacian regularization to provide robust estimates of the whole ADD.

Methods: The performance of ActiveAx was evaluated using Monte Carlo simulations on synthetic white matter samples mimicking axon distributions reported in histological studies.

Results: ActiveAx provided robust ADD reconstructions when considering the isolated intra-axonal signal. However, our formulation inherited some common microstructure imaging limitations. When accounting for the extra axonal compartment, estimated ADDs showed spurious peaks and increased variability because of the difficulty of disentangling intra and extra axonal contributions.

Conclusion: Laplacian regularization solves the ill-posedness regarding the intra axonal compartment. ActiveAx can potentially provide non-parametric and orientationally invariant ADDs from isolated intra-axonal signals. However, further work is required before ActiveAx can be applied to real data containing extra-axonal contributions, as disentangling the 2 compartment appears to be an overlooked challenge that affects microstructure imaging methods in general.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.28053DOI Listing

Publication Analysis

Top Keywords

orientationally invariant
16
non-parametric orientationally
12
microstructure imaging
12
activeax
8
activeax non-parametric
8
axon diameter
8
diameter distribution
8
add mapping
8
invariant estimates
8
laplacian regularization
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!