Background: Mechanical insufflation-exsufflation (MI-E) devices increase expiratory air flow and thereby promote increased cough peak flow (CPF) in conjunction with a cough. There is little research looking at long-term use of MI-E in subjects with neuromuscular disease (NMD), and no long-term study has reported CPF, MI-E device settings, and adherence.

Methods: We evaluated 181 patient records (130 adults, 51 children) of individuals who received a MI-E device from our center between February 2014 and February 2018. Median age (interquartile range [IQR]) was 27 (14-51) y. Duchenne muscular dystrophy (DMD), spinal muscular atrophy (SMA), and amyotrophic lateral sclerosis (ALS) were the 3 most common diagnoses.

Results: MI-E devices were provided to the weakest subjects with a CPF < 160 L/min. Median (IQR) settings were insufflation, 25 (23-30) cm HO, exsufflation -35 (-30 to -40) cm HO, insufflation time 1.5 (1.3-1.7) s, exsufflation time 1.8 (1.5-2.0) s, and pause 1.5 (1.3-2.0) s. The inspiratory flow profile was set to high in all subjects, and no subject used supplemental oxygen with the MI-E device. When comparing insufflation pressures to exsufflation pressures, a greater negative pressure was used relative to positive pressure ( < .001). When comparing insufflation to exsufflation time, there was a significantly longer exsufflation duration ( < .001). Median (IQR) CPF at the start of MI-E was 60 (10-100) L/min. There was no correlation between either insufflation or exsufflation pressures and CPF. Median (IQR) usage for the group was 60% (13.5-100%) of days for the total days. Subjects with tracheostomies or SMA type I had the greatest adherence to treatment. Median (IQR) duration of MI-E use was 17 (8.5-32) months. Ninety-six percent of subjects were receiving ventilatory support.

Conclusions: Greater exsufflation pressures than insufflation pressures, together with a shorter insufflation time than exsufflation time, were used. Predicting good adherence among the subjects was difficult. Subjects who produced daily secretions were more likely to use MI-E every day.

Download full-text PDF

Source
http://dx.doi.org/10.4187/respcare.06882DOI Listing

Publication Analysis

Top Keywords

median iqr
16
mi-e device
12
exsufflation time
12
exsufflation pressures
12
mi-e
9
mechanical insufflation-exsufflation
8
neuromuscular disease
8
mi-e devices
8
exsufflation
8
insufflation time
8

Similar Publications

Importance: Vitiligo is a chronic autoimmune disorder leading to skin depigmentation and reduced quality of life (QOL). Patients with extensive and very active disease are the most difficult to treat.

Objective: To assess the efficacy and adverse events of baricitinib combined with narrowband UV-B in adults with severe, active, nonsegmental vitiligo.

View Article and Find Full Text PDF

Importance: Patients with transthyretin (ATTR) cardiac amyloid infiltration are increasingly diagnosed at earlier disease stages with no heart failure (HF) symptoms and a wide range of cardiac amyloid infiltration.

Objective: To characterize the clinical phenotype and natural history of asymptomatic patients with ATTR cardiac amyloid infiltration.

Design, Setting, And Participants: This cohort study analyzed data of all patients at 12 international centers for amyloidosis from January 1, 2008, through December 31, 2023.

View Article and Find Full Text PDF

Capillary refill time paradoxically decreases in a blood loss shock model.

Intensive Care Med Exp

January 2025

Department of Emergency Medicine in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, 582 25, Linköping, Sweden.

Background: This study aimed to investigate whether changes in capillary refill (CR) time precede macrovascular signs of deterioration in a human model of blood loss shock. The study was conducted at the Department of Emergency Medicine in Linköping, Sweden, and involved 42 healthy volunteers aged 18-45. Participants were randomized into two provocations of applied lower body negative pressure (LBNP): a stepwise escalation protocol and a direct application protocol, to simulate gradual and acute blood loss.

View Article and Find Full Text PDF

Omnipolar mapping versus point-by-point mapping approach for catheter ablation of atrioventricular accessory pathway.

J Interv Card Electrophysiol

January 2025

Department of Cardiovascular Medicine, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Shimotsugagun, Tochigi, 321-0293, Japan.

Background: The conventional mapping approach for the atrioventricular accessory pathway (AP) involves point-by-point mapping to identify the connection sites of the AP to the atria or ventricle and accurate interpretation of local electrograms. Omnipolar mapping technology (OMT) explains how vector and wave speed are produced by using both unipolar and bipolar signals to obtain omnipolar signals, directions, and conduction velocity. The aim of this study is to verify the effectiveness of OMT for catheter ablation of AP.

View Article and Find Full Text PDF

Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.

Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!