A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multiphase Iodine Contrast-Enhanced SPECT/CT Outperforms Nonenhanced SPECT/CT for Preoperative Localization of Small Parathyroid Adenomas. | LitMetric

Purpose: The aim of this study was to assess the value of intravenously contrast-enhanced CT in conjunction with Tc-MIBI SPECT for preoperative localization of parathyroid adenoma.

Methods: One hundred ninety-two patients with primary hyperparathyroidism were enrolled in the study between May 2015 and May 2017. The patients underwent a preoperative "one-stop shop" examination with Tc-MIBI SPECT/CT by using dual time-point (10 and 90 minutes) protocol and both nonenhanced CT and contrast-enhanced CT acquisition in the arterial and venous phase, 35 and 75 seconds, respectively, after contrast medium injection start. For 149 patients, the imaging results could be correlated to those at surgery and histopathology.

Results: The median adenoma weight was 330 mg. The addition of contrast-enhanced CT increased the sensitivity from 81.1% to 89.9% (P = 0.003). The specificity of nonenhanced SPECT/CT was similar to contrast-enhanced CT (96.1% vs 97.9%; P = 0.077). For patients with uniglandular disease (n = 140, 94.0%), the sensitivity increased from 86.4% to 93.6% (P = 0.021) and the specificity from 96.2% to 97.9% (P = 0.118) by adding contrast-enhanced CT. In patients with multiglandular disease (n = 9, 6.0%), adding contrast-enhanced CT improved detection sensitivity from 42.1% to 63.2%. However, these patients were few and significance was not reached (P = 0.125).

Conclusions: In this cohort, with generally small parathyroid adenomas, the sensitivity in preoperative localization was greatly improved by adding contrast-enhanced CT to Tc-MIBI SPECT/CT.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLU.0000000000002778DOI Listing

Publication Analysis

Top Keywords

preoperative localization
12
adding contrast-enhanced
12
contrast-enhanced
8
nonenhanced spect/ct
8
small parathyroid
8
parathyroid adenomas
8
tc-mibi spect/ct
8
patients
6
spect/ct
5
multiphase iodine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!