Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In people with cystic fibrosis (CF), greater cardiorespiratory fitness is associated with improved survival and quality of life. Wearable activity monitors are a popular method of monitoring exercise, with measures of heart rate used to indicate exercise intensity. We assessed the agreement of heart rate recordings obtained using the Fitbit Charge HR, Polar® H7 heart rate sensor and Masimo SET® Rad-5v pulse oximeter with the three-lead ECG during continuous and interval exercise. Adults with CF completed two exercise sessions, of 15-min duration per session, on a cycle ergometer while wearing the previously mentioned monitors. Firstly, participants cycled at 30% of estimated peak workload ( ). Secondly, participants cycled at 1-min intervals at 60% of interspersed with 2 min of unloaded cycling. Heart rate readings on all devices were recorded at minute intervals and their agreement was analysed using the Bland-Altman method. The Polar® H7 heart rate sensor had the best agreement with three-lead ECG, with a bias of 0±1 bpm during both continuous and interval exercise. The Masimo SET® Rad-5v pulse oximeter had good agreement, with a bias of 1±7 bpm and 1±5 bpm during continuous and interval exercise, respectively. The Fitbit Charge HR demonstrated less agreement, with a bias of 9±17 bpm and 5±13 bpm during continuous and interval exercise, respectively. The Fitbit Charge HR is not recommended for assessing heart rate during exercise in adults with CF. Findings support the use of the Polar® H7 for accurate heart rate monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6819990 | PMC |
http://dx.doi.org/10.1183/23120541.00006-2019 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!