Critical Appraisal of the Impact of Oesophageal Stents in the Management of Oesophageal Anastomotic Leaks and Benign Oesophageal Perforations: An Updated Systematic Review.

World J Surg

Department of Upper Gastrointestinal Surgery, University Hospitals Birmingham NHS Foundation Trust, Area 6, 7th Floor, Queen Elizabeth Hospital Birmingham, Mindelsohn Way, Edgbaston, Birmingham, B15 2WBUK, UK.

Published: April 2020

Introduction: Endoscopic placement of oesophageal stents may be used in benign oesophageal perforation and oesophageal anastomotic leakage to control sepsis and reduce mortality and morbidity by avoiding thoracotomy. This updated systematic review aimed to assess the safety and effectiveness of oesophageal stents in these two scenarios.

Methods: A systematic literature search of all published studies reporting use of metallic and plastic stents in the management of post-operative anastomotic leaks, spontaneous and iatrogenic oesophageal perforations were identified. Primary outcomes were technical (deploying ≥ 1 stent to occlude site of leakage with no evidence of leakage of contrast within 24-48 h) and clinical success (complete healing of perforation or leakage by placement of single or multiple stents irrespective of whether the stent was left in situ or was removed). Secondary outcomes were stent migration, perforation and erosion, and mortality rates. Subgroup analysis was performed for plastic versus metallic stents and anastomotic leaks versus perforations separately.

Results: A total of 66 studies (n = 1752 patients) were included. Technical and clinical success rates were 96% and 87%, respectively. Plastic stents had significantly higher migration rates (24% vs 16%, p = 0.001) and repositioning (11% vs 3%, p < 0.001) and lower technical success (91% vs 95%, p = 0.032) than metallic stents. In patients with anastomotic leaks, plastic stents were associated with higher stent migration (26% vs 15%, p = 0.034), perforation (2% vs 0%, p = 0.013), repositioning (10% vs 0%, p < 0.001), and lower technical success (95% vs 100%, p = p = 0.002). In patients with perforations only, plastic stents were associated with significantly lower technical success (85% vs 99%, p < 0.001).

Conclusions: Covered metallic oesophageal stents appear to be more effective than plastic stents in the management of oesophageal perforation and anastomotic leakage. However, quality of evidence of generally poor and high-quality randomised trial is needed to further evaluate best management option for oesophageal perforation and anastomotic leakage.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00268-019-05259-6DOI Listing

Publication Analysis

Top Keywords

oesophageal stents
12
anastomotic leaks
12
oesophageal
8
stents management
8
oesophageal anastomotic
8
benign oesophageal
8
oesophageal perforations
8
updated systematic
8
systematic review
8
plastic stents
8

Similar Publications

Background: We aimed to evaluate and compare the rise in the temperature for the safety of the kidney parenchyma on firing the Holmium: Yttrium Aluminium Garnet laser and the Thulium Fiber Laser during laser lithotripsy in humans.

Method: We included 30 pre-stented patients with renal calculi undergoing Retrograde intra-renal surgery. They were randomized into two groups - 15 patients underwent holmium laser lithotripsy and 15 patients underwent TFL laser lithotripsy.

View Article and Find Full Text PDF

We present a case of an 80-year-old female who presented with chest pain, vomiting and night sweats a few weeks post thoracic endovascular aortic aneurysm repair (TEVAR). A computed tomography (CT) scan demonstrated a type 1B endoleak for which she underwent a repeat TEVAR. Postoperatively, she developed fever, dysphagia, haematemesis and melaena.

View Article and Find Full Text PDF

Rationale: Aortoesophageal fistula (AEF) is an exceedingly rare yet critically life-threatening condition, with mortality rates nearing 100% if not addressed promptly. AEF often develops in the context of thoracic aortic aneurysms, esophageal malignancies, or as a complication of foreign body ingestion and prior thoracic aortic surgeries. This study reports an exceptionally severe and clinically rare case of AEF associated with a pseudaneurysm induced by esophageal stenting.

View Article and Find Full Text PDF

Endoscopic dissection of an esophageal stent.

Gastrointest Endosc

January 2025

Department of Gastroenterology, National Clinical Research Center of Infectious Disease, The Third People's Hospital of Shenzhen, The Second Affiliated Hospital of Southern University of Science and Technology,Shenzhen, China. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!