A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated nephelometry of fibrinogen: analytical performance and observations during thrombolytic therapy. | LitMetric

Automated nephelometry of fibrinogen: analytical performance and observations during thrombolytic therapy.

Clin Chem

Department of Clinical Laboratories, Catharina Hospital, Eindhoven, The Netherlands.

Published: October 1988

We evaluated the performance of an automated nephelometric determination of fibrinogen, which is an integral part of the prothrombin time assay, in a new coagulation analyzer, the ACL-810 (Instrumentation Laboratory). Results were compared with those by a total clottable protein assay and with the thrombin clotting time assay for fibrinogen. In normal and slightly abnormal plasma, the performance of the ACL method was quite satisfactory (CV 3-10%). However, in abnormal plasma (prolonged prothrombin times because of heparin or oral anticoagulants) the accuracy of the ACL method was poor. Nor could the instrument determine fibrinogen in clearly lipemic plasma. In plasma containing high concentrations of fibrin(ogen) degradation products (FDP), collected during thrombolytic therapy with streptokinase-containing drugs, the ACL method gave spuriously high values for fibrinogen concentration. We determined that this was mainly because of interference by intermediate FDP (fragment Y). Finally, we demonstrated that early FDP (fragment X) increased the ACL results for fibrinogen to the same extent as in the total clottable protein method and that late FDP (fragments D and E) affected the thrombin clotting time method, but not the ACL fibrinogen determination.

Download full-text PDF

Source

Publication Analysis

Top Keywords

acl method
12
fibrinogen
8
thrombolytic therapy
8
time assay
8
total clottable
8
clottable protein
8
thrombin clotting
8
clotting time
8
abnormal plasma
8
fdp fragment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!