Concerns have been raised regarding the lack of validation on consumer-marketed health-monitoring devices. An investigation to characterize current health monitoring devices was carried out in the laboratory using widely accepted clinical and industry criteria. In total, 16 unique devices were examined. These devices were assessed according to their sensing modalities: step count, blood pressure, body temperature, electrocardiogram, blood oxygen saturation, and respiratory rate. Devices were tested at rest and immediately following exercise. Our results revealed that only four devices meet target requirements for accuracy. The AliveCor, a portable ECG monitor, accurately detected the heart rate for 87% of all recordings. To meet the target criterion for accuracy, the heart rate must be within ± 5 beats/minute or 10% of the standard measurement, whichever is lower. The Withings Pulse Ox, the Tinké, and the Santamedical SM-110 measured blood oxygen saturation with 2.1, 2.6, and 1.4 root-mean-square (rms) error, respectively. For blood oxygen saturation, the device should demonstrate rms error of < 3%. However, the Withings Pulse Ox and the Tinké failed to meet the accuracy criteria for their alternative biosensing capabilities: step count and respiratory rate, respectively. We conclude that the use of consumer-marketed health-monitoring devices for clinical or medical purposes should be undertaken with caution, especially in the absence of FDA or comparable clearance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1615/CritRevBiomedEng.2019026110 | DOI Listing |
Adv Sci (Weinh)
January 2025
Cancer Institute (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, China.
The most prevalent types of lymphomas are B cell lymphomas (BCL). Newer therapies for BCL have improved the prognosis for many patients. However, approximately 30% with aggressive BCL either remain refractory or ultimately relapse.
View Article and Find Full Text PDFClin Case Rep
January 2025
Emergency Intensive Care Unit Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China Chengdu Sichuan China.
We report a rare complication of left ventricular giant thrombus in a patient with fulminant myocarditis after venoarterial extracorporeal membrane oxygenation therapy. This case report offers simple anticoagulant treatment experiences to eliminate significant LV thrombosis in patient undergoing extracorporeal membrane oxygenation, so that patients do not need surgery.
View Article and Find Full Text PDFPatients presenting with severe acute cardiogenic pulmonary edema with hypoxia commonly require intubation until heart failure treatments take effect. A new term describing similar condition is called sympathetic crashing acute pulmonary edema (SCAPE). It is also called Flash pulmonary edema.
View Article and Find Full Text PDFFed Pract
October 2024
Veterans Affairs Boston Healthcare System, West Roxbury, Massachusetts.
: A 65-year-old male veteran presented to the Veterans Affairs Boston Healthcare System (VABHS) emergency department with progressive fatigue, dyspnea on exertion, lightheadedness, and falls over the last month. New bilateral lower extremity numbness up to his knees developed in the week prior to admission and prompted him to seek care. Additional history included 2 episodes of transient loss of consciousness resulting in falls and a week of diarrhea, which had resolved.
View Article and Find Full Text PDFIEEE Biomed Circuits Syst Conf
October 2024
Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
The proper functioning of the respiratory system is evaluated by monitoring the exchange of blood oxygen and carbon dioxide. While wearable devices for monitoring both blood oxygen and carbon dioxide are emerging, wearable carbon dioxide monitors remain relatively rare. This paper introduces a novel wearable prototype that integrates the measurement of transcutaneous carbon dioxide and peripheral blood oxygen saturation on a miniaturized custom-designed printed circuit board.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!