A review on nanomaterial-based field effect transistor technology for biomarker detection.

Mikrochim Acta

Biosensor Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, P.O. Box 14395/1179, Tehran, Islamic Republic of Iran.

Published: November 2019

Field effect transistor (FET) based sensors have attractive features such as small size, ease of mass production, high versatility and comparably low costs. Over the last decade, many FET type biosensors based on various nanomaterials (e.g. silicon nanowires, graphene, and transition metal dichalcogenides) have been developed to detect various classes of biomolecular targets due to their integration into portable and rapid test systems, both for use in the clinical lab and in point-of-care testing. This review (with 197 refs.) starts with an introduction into the specific features of FET biosensor technology. This is followed by a description of the essentials of methods for immobilization of recognition elements. The next section discusses the progress that has been made in FET based biosensors using semiconducting nanostructures composed of silicon, graphene, metal oxides, and transition metal dichalcogenides. A further section is devoted to microfluidic systems combined with FET biosensors. We then emphasize the biosensing applications of these diagnostic devices for analysis of clinically relevant biomarkers, specifically to sensing of neurotransmitters, metabolites, nucleic acids, proteins, cancer and cardiac biomarkers. Two tables are presented which summarize advances in applications of 1D and 2D nanomaterial-based FETs for biomarker sensing. A concluding section summarizes the current status, addresses current challenges, and gives perspective trends for the field. Graphical abstract Field effect transistor devices based on the use of 1D and 2D semiconductor nanostructures (so called nano-FETs) are making use of materials including silicon nanowires, graphene, zinc oxide, indium oxide, titanium oxide, and molybdenum disulfide that are further modified with recognition elements for biosensing application.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-019-3850-6DOI Listing

Publication Analysis

Top Keywords

field transistor
12
fet based
8
silicon nanowires
8
nanowires graphene
8
transition metal
8
metal dichalcogenides
8
recognition elements
8
fet
5
review nanomaterial-based
4
field
4

Similar Publications

Multi-gate neuron-like transistors based on ensembles of aligned nanowires on flexible substrates.

Nano Converg

January 2025

Bendable Electronics and Sustainable Technologies (BEST) Group, Electrical and Computer Engineering Department, Northeastern University, Boston, MA, 02115, USA.

The intriguing way the receptors in biological skin encode the tactile data has inspired the development of electronic skins (e-skin) with brain-inspired or neuromorphic computing. Starting with local (near sensor) data processing, there is an inherent mechanism in play that helps to scale down the data. This is particularly attractive when one considers the huge data produced by large number of sensors expected in a large area e-skin such as the whole-body skin of a robot.

View Article and Find Full Text PDF

New flow control elements in capillaric circuits are key to achieving ever more complex lab-on-a-chip functionality while maintaining their autonomous and easy-to-use nature. Capillary field effect transistors valves allow for flow in channels to be restricted and cut off utilising a high pressure triggering channel and occluding air bubble. The reversible capillary field effect transistor presented here provides a new element that can restore fluid flow in closed microchannels autonomous circuit feedback.

View Article and Find Full Text PDF

Multivalued logic (MVL) systems, in which data are processed with more than two logic values, are considered a viable solution for achieving superior processing efficiency with higher data density and less complicated system complexity without further scaling challenges. Such MVL systems have been conceptually realized by using negative transconductance (NTC) devices whose channels consist of van der Waals (vdW) heterojunctions of low-dimensional semiconductors; however, their circuit operations have not been quite ideal for driving multiple stages in real circuit applications due to reasons such as a reduced output swing and poorly defined logic states. Herein, we demonstrate ternary inverter circuits with near rail-to-rail swing and three distinct logic states by employing vdW p-n heterojunctions of single-walled carbon nanotubes (SWCNT) and MoS where the SWCNT layer completely covers the MoS layer.

View Article and Find Full Text PDF

Rapid indirect detection of N-lactoyl-phenylalanine using dual DNA biosensors based on solution-gated graphene field-effect transistor.

Biosens Bioelectron

January 2025

School of Food and Biological Engineering, Hefei University of Technology, Hefei, Anhui, 230009, China; Engineering Research Center of Bio-process, Ministry of Education, Hefei University of Technology, Hefei, 230009, China. Electronic address:

As obesity rates continue to rise, there is an increasing focus on reducing obesity through exercise. People are becoming more aware of the importance of weight loss through physical activity. However, the effectiveness of exercise can vary significantly among individuals, making it challenging to evaluate its impact.

View Article and Find Full Text PDF

For potential application in advanced memory devices such as dynamic random-access memory (DRAM) or NAND flash, nanolaminated indium oxide (In-O) and gallium oxide (Ga-O) films with five different vertical cation distributions were grown and investigated by using a plasma-enhanced atomic layer deposition (PEALD) process. Specifically, this study provides an in-depth examination of how the control of individual layer thicknesses in the nanolaminated (NL) IGO structure impacts not only the physical and chemical properties of the thin film but also the overall device performance. To eliminate the influence of the cation composition ratio and overall thickness on the IGO thin film, these parameters were held constant across all conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!