Follow-up ultrasound in second-trimester low-positioned anterior and posterior placentae: prospective cohort study.

Ultrasound Obstet Gynecol

Amsterdam UMC, University of Amsterdam, Department of Obstetrics and Gynaecology, Amsterdam, The Netherlands.

Published: November 2020

Objectives: The majority of cases of placenta previa or a low-lying placenta in the second trimester will have a normal placental position in the third trimester. The aim of this study was to assess the accuracy of the distance between the placenta and the internal os of the cervix (IOD) in the second trimester for the prediction of third-trimester low-positioned placenta, and to define a cut-off value at which all cases of third-trimester low-positioned placenta are identified.

Methods: This was a prospective cohort study including women undergoing a transvaginal ultrasound examination between 18 and 24 weeks' gestation who had a low-positioned placenta, defined as an IOD of < 20 mm. Low-positioned placenta included placenta previa, defined as a placenta covering the internal os of the cervix, and a low-lying placenta, defined as a placenta lying near to (within 20 mm) but not overlying the internal os. All women were re-evaluated in the third trimester. Relative risks for a low-positioned placenta in the third trimester were calculated for women with placenta previa vs a low-lying placenta, posterior vs anterior placenta and positive vs negative history of Cesarean section. Multilevel likelihood ratios for ranges of IOD in the prediction of a low-positioned placenta in the third trimester were calculated separately for anteriorly and posteriorly located placentae. Corresponding receiver-operating-characteristics curves were constructed.

Results: In total, 958 women were included in the study. In the second trimester, placentae were more frequently located on the posterior side (62.0%) than on the anterior side (38.0%). In the third trimester, 48/958 (5.0%) placentae persisted as a low-positioned placenta. Women with placenta previa in the second trimester had a higher risk of a low-positioned placenta in the third trimester than did those with a low-lying placenta in the second trimester (37/181 (20.4%) vs 11/777 (1.4%); relative risk (RR), 17.9 (95% CI, 8.9-36.0)). Women with a posterior placenta had a higher risk of a low-positioned placenta in the third trimester than did those with an anterior placenta (38/594 (6.4%) vs 10/364 (2.7%); RR, 2.4 (95% CI, 1.2-4.9)), as did women with a history of Cesarean section compared with those without such a history (14/105 (13.3%) vs 34/853 (4.0%); RR, 3.7 (95% CI, 1.9-7.2)). The cut-off value of IOD in the second trimester to identify all cases of an abnormally located placenta in the third trimester was 15.5 mm for posteriorly located placentae, while for anteriorly located placentae the IOD cut-off was lower, namely -4.5 mm, representing a 4.5-mm overlap of the placental edge over the internal os of the cervix.

Conclusions: With incorporation of a safety margin of 5 mm and ensuring that all women with placenta previa undergo a follow-up scan, we recommend lowering the IOD cut-off value for follow-up in cases of an anterior low-positioned placenta from 20 to 5 mm, which would decrease the number of unnecessary follow-up ultrasound examinations without missing any high-risk women. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7702149PMC
http://dx.doi.org/10.1002/uog.21903DOI Listing

Publication Analysis

Top Keywords

low-positioned placenta
12
prospective cohort
8
cohort study
8
second trimester
8
third-trimester low-positioned
8
placenta
6
follow-up ultrasound
4
ultrasound second-trimester
4
low-positioned
4
second-trimester low-positioned
4

Similar Publications

Low placenta at the mid trimester anomaly scan-A cause for concern?

J Clin Ultrasound

January 2025

Department of Fetal Medicine, Fernandez Hospital, Hyderabad, India.

Article Synopsis
  • The study aimed to evaluate how effective internal os distance (IOD) measurements during mid-pregnancy scans can predict low-positioned placenta in later pregnancy and establish a cut-off point for identifying this condition.
  • A prospective cohort study followed women with low-positioned placenta (IOD < 20 mm) through to childbirth, analyzing risks based on placental location and cesarean history.
  • Findings indicated that most women (93.42%) with low-positioned placenta at mid-trimester had normal placements by the third trimester, suggesting that specific IOD cut-off points could help with early diagnosis and management.
View Article and Find Full Text PDF

Objectives: The majority of cases of placenta previa or a low-lying placenta in the second trimester will have a normal placental position in the third trimester. The aim of this study was to assess the accuracy of the distance between the placenta and the internal os of the cervix (IOD) in the second trimester for the prediction of third-trimester low-positioned placenta, and to define a cut-off value at which all cases of third-trimester low-positioned placenta are identified.

Methods: This was a prospective cohort study including women undergoing a transvaginal ultrasound examination between 18 and 24 weeks' gestation who had a low-positioned placenta, defined as an IOD of < 20 mm.

View Article and Find Full Text PDF

Low-positioned placentas which are located in the lower uterine segment (LUS), either a low-lying placenta or a placenta previa, are associated with increased obstetric risks. However, most second trimester low-positioned placentas resolve during pregnancy and have a higher position in the third trimester, without posing any risks. We performed a systematic review and meta-analysis to evaluate the proportion of second trimester low-positioned placentas that have a position towards the fundus in the third trimester.

View Article and Find Full Text PDF

A prospective investigation of the problem of low placentation in mid-trimester, in uncomplicated pregnancies was performed. 773 pregnant women were included and 70 (9.1%) had a low-positioned placenta, defined as a placenta reaching or partially covering the cervical os, diagnosed by ultrasound between the 19th and 21st week of pregnancy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!