Sex and age are two elements in the establishment of a biological profile for forensic identification. While the pelvic bones are the most ideal structures for sex estimation, the condition of a body is not always ideal due to the nature of death, such as in mass disasters, or postmortem processes. This study utilized CT scans and resultant 3D models of 100 male and 100 female adults of known ages ranging from 18 to 98 years old to collect volumetric and Hounsfield unit measurements of the proximal femur. Equations were created to establish logistic regression models for sex estimation and linear regression models for age estimation. The resultant sex estimation method had an accuracy of 93.5% and utilized the volume of the proximal femur. This study provides three linear regression models for age with an accuracy range of 86%-92% ±12 years. As imaging technologies are increasingly adopted for forensic purposes, the power of 3D data will provide the opportunity for more quantitative and reproducible analyses. The proposed method for sex and age estimation provides a reliable tool that can be utilized in both day-to-day casework and disaster victim identification.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1556-4029.14216 | DOI Listing |
Sci Rep
January 2025
Department of Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.
View Article and Find Full Text PDFBone
January 2025
ARTORG Centre for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Osteoporosis is the most common bone metabolic unbalance, leading to fragility fractures, which are known to be associated with structural changes in the bone. Cortical bone accounts for 80 % of the skeleton mass and undergoes remodeling throughout life, leading to changes in its thickness and microstructure. Although many studies quantified the different cortical bone structures using CT techniques (3D), they are often realised on a small number of samples.
View Article and Find Full Text PDFInjury
January 2025
Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Denmark; Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital - University Hospital of Southern Denmark, Denmark; Department of Clinical Research, University of Southern Denmark, Denmark.
Background: Proximal femoral fractures has been associated with high mortality risk, while little is known about more distal lower extremity fractures. The aim was to report 30- and 365-days mortality in surgically treated lower extremity fractures in individuals above 65 years.
Materials And Methods: We extracted data from the Danish National Patient Register on all surgically treated lower extremity fracture in the period 1998-2017.
J Clin Med
January 2025
Department of Orthopaedic and Trauma Surgery, Institute of Medical Sciences, University of Opole, 45-040 Opole, Poland.
Developmental knee joint deformities are a common problem in pediatric orthopedics. Children with a valgus or varus deformity of the distal femur or the proximal tibia are commonly treated with hemiepiphysiodesis. Gait analysis in patients with lower limb deformities plays an important role in clinical practice.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!