Background Contemporary outcomes of transcatheter aortic valve replacement (TAVR) in nonagenarians are unknown. Methods and Results We identified 13 544 nonagenarians (aged 90-100 years) who underwent TAVR between 2012 and 2016 using Medicare claims. Generalized estimating equations were used to study the change in short-term outcomes among nonagenarians over time. We compared outcomes between nonagenarians and non-nonagenarians undergoing TAVR in 2016. A mixed-effect multivariable logistic regression was performed to determine predictors of 30-day mortality in nonagenarians in 2016. A center was defined as a if it performed ≥100 TAVR procedures per year. After adjusting for changes in patients' characteristics, risk-adjusted 30-day mortality declined in nonagenarians from 9.8% in 2012 to 4.4% in 2016 (<0.001), whereas mortality for patients <90 years decreased from 6.4% to 3.5%. In 2016, 35 712 TAVR procedures were performed, of which 12.7% were in nonagenarians. Overall, in-hospital mortality in 2016 was higher in nonagenarians compared with younger patients (2.4% versus 1.7%, <0.05) but did not differ in analysis limited to high-volume centers (2.2% versus 1.7%; odds ratio: 1.33; 95% CI, 0.97-1.81; =0.07). Important predictors of 30-day mortality in nonagenarians included in-hospital stroke (adjusted odds ratio [aOR]: 8.67; 95% CI, 5.03-15.00), acute kidney injury (aOR: 4.11; 95% CI, 2.90-5.83), blood transfusion (aOR: 2.66; 95% CI, 1.81-3.90), respiratory complications (aOR: 2.96; 95% CI, 1.52-5.76), heart failure (aOR: 1.86; 95% CI, 1.04-3.34), coagulopathy (aOR: 1.59; 95% CI, 1.12-2.26; <0.05 for all). Conclusions Short-term outcomes after TAVR have improved in nonagenarians. Several procedural complications were associated with increased 30-day mortality among nonagenarians.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6898796PMC
http://dx.doi.org/10.1161/JAHA.119.013685DOI Listing

Publication Analysis

Top Keywords

outcomes transcatheter
8
transcatheter aortic
8
aortic valve
8
valve replacement
8
outcomes nonagenarians
8
30-day mortality
8
nonagenarians
7
temporal trends
4
trends clinical
4
outcomes
4

Similar Publications

Background: Mitral annular calcification (MAC) is characterized by severe calcification of mitral annulus and might be associated with both mitral regurgitation and stenosis. It is technically challenging for both surgical and percutaneous approach and is burdened by high mortality.

Case Summary: The present case report describes a complex case of mitral steno-insufficiency (baseline transvalvular gradient = 5 mmHg, effective regurgitant orifice area 0.

View Article and Find Full Text PDF

Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.

Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.

View Article and Find Full Text PDF

Transcatheter Aortic Valve Replacement in Hypertrophic Cardiomyopathy: A Systematic Review and Meta-Analysis.

Catheter Cardiovasc Interv

January 2025

Division of Cardiovascular Diseases, Bridgeport Hospital, Yale New Haven Health, Bridgeport, Connecticut, USA.

Background: The co-existence of severe aortic stenosis (AS) and hypertrophic cardiomyopathy (HCM) is not uncommon. Surgical intervention is the gold standard management. Patients with high surgical risk might undergo transcatheter aortic valve replacement (TAVR).

View Article and Find Full Text PDF

Outcomes and Impact of Device Iterations in Mitral Valve Transcatheter Edge-to-Edge Repair: The REPAIR Study.

JACC Cardiovasc Interv

November 2024

Department of Cardiology, Heart Center, Faculty of Medicine, University of Cologne, Cologne, Germany. Electronic address:

Background: The PASCAL P10 system for mitral valve transcatheter edge-to-edge repair has undergone iterations, including introduction of the narrower Ace implant and the Precision delivery system.

Objectives: The study sought to evaluate outcomes and the impact of PASCAL mitral valve transcatheter edge-to-edge repair device iterations.

Methods: The REPAIR (REgistry of PAscal for mltral Regurgitation) study is an investigator-initiated, multicenter registry including consecutive patients with mitral regurgitation (MR) treated from 2019 to 2024.

View Article and Find Full Text PDF

Background: Protruding coronary artery stents can adversely affect transcatheter aortic valve replacement (TAVR) procedure. Current evidence on the topic is limited.

Aims: We aim to study the clinical feasibility and safety of flaring of protruding coronary artery stents before TAVR to reduce interaction with transcatheter heart valves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!