Diamond Etching Beyond 10 μm with Near-Zero Micromasking.

Sci Rep

London Centre for Nanotechnology & Department of Electronic and Electrical Engineering, University College London, 17-19 Gordon Street, WC1H 0AH, London, UK.

Published: October 2019

To exploit the exceptional properties of diamond, new high quality fabrication techniques are needed to produce high performing devices. Etching and patterning diamond to depths beyond one micron has proven challenging due to the hardness and chemical resistance of diamond. A new cyclic Ar/O - Ar/Cl ICP RIE process has been developed to address micromasking issues from the aluminium mask by optimising the proportion of O in the plasma and introducing a preferential "cleaning" step. High quality smooth features up to, but not limited to, 10.6 μm were produced with an average etched surface roughness of 0.47 nm at a diamond etch rate of 45 nm/min and 16.9:1 selectivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6821859PMC
http://dx.doi.org/10.1038/s41598-019-51970-8DOI Listing

Publication Analysis

Top Keywords

high quality
8
diamond
5
diamond etching
4
etching 10 μm
4
10 μm near-zero
4
near-zero micromasking
4
micromasking exploit
4
exploit exceptional
4
exceptional properties
4
properties diamond
4

Similar Publications

Testing an Electronic Patient-Reported Outcome Platform in the Context of Traumatic Brain Injury: PRiORiTy Usability Study.

JMIR Form Res

January 2025

Centre for Patient Reported Outcomes Research, Institute of Applied Health Research, University of Birmingham, Birmingham, United Kingdom.

Background: Traumatic brain injury (TBI) is a significant public health issue and a leading cause of death and disability globally. Advances in clinical care have improved survival rates, leading to a growing population living with long-term effects of TBI, which can impact physical, cognitive, and emotional health. These effects often require continuous management and individualized care.

View Article and Find Full Text PDF

Count-rate management in I SPECT/CT calibration.

EJNMMI Phys

January 2025

Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.

Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.

View Article and Find Full Text PDF

Purpose: Prior sperm DNA fragmentation index (DFI) thresholds for diagnosing male infertility and predicting assisted reproduction technology (ART) outcomes fluctuated between 15 and 30%, with no agreed standard. This study aimed to evaluate the impact of the sperm DFI on early embryonic development during ART treatments and establish appropriate DFI cut-off values.

Methods: Retrospectively analyzed 913 couple's ART cycles from 2021 to 2022, encompassing 1,476 IVF and 295 ICSI cycles, following strict criteria.

View Article and Find Full Text PDF

Background: First responders exist in several countries and have been a prehospital emergency medical resource in Norwegian municipalities since 2010. However, the Norwegian system has not yet been studied. The aim of this study was to describe the first responder system in Central Norway and how it is used as a supplement to emergency medical services (EMS).

View Article and Find Full Text PDF

The incidence of inflow and drain pain and associated risk factors for patients on peritoneal dialysis.

BMC Nephrol

January 2025

Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, 58th, Zhongshan Road II, Guangzhou, 510080, Guangdong, PR China.

Background: The high prevalence and prolonged duration of inflow pain and drain pain experienced by peritoneal dialysis (PD) patients following PD catheter implantation impact their quality of life. However, there is limited data on the frequency and predisposing factors of these pains in the Chinese population undergoing peritoneal dialysis.

Methods: This study encompassed individuals who underwent peritoneal dialysis catheter implantation at our institution from September 1, 2023, to March 31, 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!