Method development for quantitative determination of seven statins including four active metabolites by means of high-resolution tandem mass spectrometry applicable for adherence testing and therapeutic drug monitoring.

Clin Chem Lab Med

Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Homburg, Germany.

Published: April 2020

AI Article Synopsis

Article Abstract

Background Statins are used to treat and prevent cardiovascular diseases (CVDs) by reducing the total serum cholesterol concentration. Unfortunately, dose-related side effects and sub-optimal response, attributed to non-adherence amongst others, were described. Therefore, a fast and sensitive liquid chromatography-high-resolution tandem mass spectrometry (LC-HRMS/MS) method for adherence testing and therapeutic drug monitoring of all currently marketed statins and their active metabolites in human blood plasma should be developed, validated and tested for applicability. Methods Atorvastatin, fluvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, and simvastatin, as well as ortho- and para-hydroxy-atorvastatin, lovastatin hydroxy acid and simvastatin hydroxy acid were included and several internal standards (IS) tested. Validation was performed according to the guideline of the European Medicines Agency including selectivity, carry-over, accuracy, precision, matrix effects, dilution integrity and analyte stability. Finally, applicability was tested using 14 patient samples submitted for regular toxicological analysis. Results Due to an analytical interference of atorvastatin-d5, diazepam-d5 and pentobarbital-d5 were chosen as IS for positive and negative ionization mode, respectively. All statins and metabolites fulfilled the validation acceptance criteria except for fluvastatin, which could not be quantified reliably and reproducibly, most probably due to instability. Analyses of human plasma samples revealed concentrations of statins and metabolites below the reference plasma concentrations in the case of eight patients. However, nothing was known concerning patients' adherence and time between intake and sampling. Conclusions An LC-HRMS/MS method for identification and quantification of atorvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, simvastatin and four active metabolites was successfully developed and applicability demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2019-0763DOI Listing

Publication Analysis

Top Keywords

active metabolites
12
tandem mass
8
mass spectrometry
8
adherence testing
8
testing therapeutic
8
therapeutic drug
8
drug monitoring
8
lc-hrms/ms method
8
lovastatin pitavastatin
8
pitavastatin pravastatin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!