: Safe practice is important for patients with neck pain, with the potential for injury to cervical arteries. Cervical manipulation or end range techniques/positions may place considerable strain on the arteries. Altered integrity of the arterial wall may render them more susceptible to minor trauma, particularly in the upper cervical region. Screening of blood flow velocity is limited for predicting those at risk. Examining properties of the cervical arterial wall (stiffness characteristics) and their response to head movement may provide an alternate measure of arterial susceptibility.: To investigate whether shear wave ultrasound elastography can detect any changes in internal carotid (ICA) and vertebral (VA) arterial wall stiffness in neutral compared with contralateral head rotation.: Observational study: Shear wave ultrasound elastography was used to measure the stiffness of the ICA and VA. Shear wave velocity (m/s), indicative of arterial stiffness, was measured in both arteries proximally (C3-4) and distally (C1-2) in neutral and contralateral head rotation as were intimal thickness (mm) and flow velocity (cm/s).: Thirty participants (20-62 years) were successfully imaged. The VA was stiffer than ICA and it became significantly stiffer in contralateral rotation (p = 0.05). The ICA became significantly less stiff (p = 0.01). Effects were more apparent at C1-2 but significant in the ICA only (p = 0.03). Flow velocity and intimal thickness were unchanged in rotation.: Changes in VA and ICA arterial wall stiffness can be measured with shear wave ultrasound elastography. This measure may ultimately help identify arteries with greater vulnerability to rotational stresses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7170308PMC
http://dx.doi.org/10.1080/10669817.2019.1686210DOI Listing

Publication Analysis

Top Keywords

arterial wall
20
shear wave
20
wall stiffness
16
flow velocity
12
wave ultrasound
12
ultrasound elastography
12
changes internal
8
internal carotid
8
vertebral arterial
8
head movement
8

Similar Publications

Prevention of sufentanil-induced cough during induction of general anesthesia by low-dose esketamine.

BMC Anesthesiol

January 2025

Department of Anesthesiology, Air Force Medical Center, No.30 Fucheng Road, Haidian District, Beijing, 100142, China.

Background: Sufentanil is commonly used to induce general anaesthesia due to its rapid onset of action, strong analgesic effect, long-lasting effect, and stable haemodynamics; however, it often induces cough, increasing the risk of anaesthesia. This study aimed to investigate the preventive effect of low-dose esketamine on sufentanil-induced cough.

Methods: This randomised, double-blind, placebo-controlled clinical study was conducted at the Air Force Medical Center between September 2023 and May 2024.

View Article and Find Full Text PDF

To establish the extent, distribution and frequency of in-vivo vessel wall [Ga]Ga-PentixaFor uptake and to determine its relationship with calcified atherosclerotic plaque burden (CAP) and cardiovascular risk factors (CVRF). 65 oncological patients undergoing [Ga]Ga-PentixaFor PET/CT were assessed. Radiotracer uptake (target-to-background ratio [TBR]) and CAP burden (including number of CAP sites, calcification circumference and thickness) in seven major vessel segments per patient were determined.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).

Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).

View Article and Find Full Text PDF

Aneurysm modeling and simulation play an important role in many specialist areas in the field of medicine such as surgical education and training, clinical diagnosis and prediction, and treatment planning. Despite the considerable effort invested in developing computational fluid dynamics so far, visual simulation of blood flow dynamics in aneurysms, especially the under-explored aspect of bifurcation aneurysms, remains a challenging issue. To alleviate the situation, this study introduces a novel Smoothed Particle Hydrodynamics (SPH)-based method to model and visually simulate blood flow, bifurcation progression, and fluid-structure interaction.

View Article and Find Full Text PDF

Background: Small conductance Ca activated K channels (K2.3) are important regulators of vascular function. They provide Ca-dependent hyperpolarization of the endothelial membrane potential, promoting agonist-induced vasodilation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!