A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterization of 6-bromoferulic acid as a novel common-use matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. | LitMetric

Rationale: Ferulic acid (FA) is a standard matrix used for analyzing proteins. In this study, the ability of a halogenated FA to serve as an effective MALDI matrix was investigated. Various halogenated FAs were synthesized, and the characteristics and performance of each were compared with those of the standard matrices α-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydrobenzoic acid (DHBA).

Methods: The abilities of 6-bromoferulic acid (6-BFA), ferulic acid (FA), and eight other halogenated FA derivatives to ionize eight synthetic peptides were examined. Absorption measurements, MM2 structure optimizations, and proton affinity (PA) calculations were also performed for 6-BFA and FA. The suitabilities of these compounds as matrices for matrix-assisted laser desorption/ionization (MALDI) for lipids, sugar chains, polymers, cyanocobalamin, synthetic peptides, and tryptic peptides originating from two types of serum proteins were also tested.

Results: The 6-position of FA was found to be the best site for introducing a bromine because the generated compound allowed facile detection of cyanocobalamin and several peptides. 6-BFA exhibited good sensitivity for large peptides (3-5 kDa) and peptides containing acidic amino acids or proline. 6-BFA was also shown to be a suitable matrix for tandem mass spectrometry (MS/MS) analysis when using MALDI time-of-flight (TOF) mass spectrometry (MS) with a quadrupole ion trap (QIT) system.

Conclusions: The properties of 6-BFA as a MALDI matrix differed from those of DHBA and CHCA. 6-BFA appears to be a useful matrix for de novo sequencing using MALDI-QIT-TOF-MS.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.8636DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
6-bromoferulic acid
8
matrix-assisted laser
8
laser desorption/ionization
8
ferulic acid
8
maldi matrix
8
synthetic peptides
8
acid
6
matrix
6
6-bfa
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!