Background: Minimally invasive single-port surgery is often associated with large incisions up to 2-3 cm, complicated handling due to the lack of triangulation, and instrument crossing. Aim of this prospective study was to perform true single-port surgery (cholecystectomy) without the use of assisting trocars using a new surgical platform that allows for triangulation incorporating robotic features, and to measure the perioperative outcome and cosmetic results.
Methods: As the first European site after FDA and CE-mark approval, the new device has been introduced to our academic center. In patients with cholecystitis and cholecystolithiasis, the operation was performed through only one 15-mm trocar. For patients safety, intraoperative cholangiography using intravenous ICG and a standard Stryker 1588 system was routinely performed.
Results: Symphonx was used in n = 12 patients for abdominal surgery (6 females, mean age 42.5 [30-77], mean BMI 26.2 [19.3-38.9]. A total of 8 patients underwent surgery using no additional ports besides the 15-mm trocar; in the remaining patients, one assisting instrument (3-5 mm) was used. Mean OR time was 107 [72-221] minutes. The postoperative course was uneventful in 11 patients; in one patient, a seroma at the surgical site required interventional drainage 1 month postoperatively. No intraoperative complications occurred.
Conclusion: This is the first human case series using the commercially available symphonX platform for abdominal laparoscopic surgery and the first series using the system without assisting instruments. Laparoscopic cholecystectomy in patients with cholecystitis and cholecystolithiasis using the symphonX platform through only one 15-mm trocar is feasible, safe, and more cost-efficient compared to robotic platforms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-019-07229-4 | DOI Listing |
Surg Endosc
January 2025
Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Boston, Massachusetts and Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA.
Background: Endoscopic closure techniques are effective and safe in the management of transmural gastrointestinal defects. However, there is a paucity of data regarding their comparative effectiveness. This study aimed to compare the efficacy and safety of several new-generation, endoscopic closure devices in a pre-clinical model.
View Article and Find Full Text PDFOtol Neurotol
December 2024
Department of Otolaryngology-Head and Neck Surgery, Stanford University.
Objective: Develop an artificial intelligence (AI) model to track otologic instruments in mastoidectomy videos.
Study Design: Retrospective case series.
Setting: Tertiary care center.
Am J Orthod Dentofacial Orthop
July 2024
Division of Public and Child Dental Health, Dublin Dental University Hospital, The University of Dublin, Trinity College Dublin, Dublin, Ireland. Electronic address:
Introduction: The objective of this study was to investigate the accuracy of palatal miniscrew insertion, evaluating the effect of guide fabrication and surgical placement.
Methods: Guided insertion of bilateral paramedian palatal miniscrews was undertaken using Appliance Designer software (3Shape, Copenhagen, Denmark). A resin surgical guide (P Pro Surgical Guide; Straumann AG, Basel, Switzerland) was used.
Urology
July 2024
Istanbul University, Istanbul Faculty of Medicine, Urology Department, Istanbul, Turkey. Electronic address:
Background: The management of kidney stones, particularly those in the renal pelvis, is a critical aspect of urology. The European Association of Urology guidelines recommend Extracorporeal Shock Wave Lithotripsy or Endourology methods, encompassing Percutaneous Nephrolithotomy and Ureterorenoscopy (URS), for stones ranging from 10-20 mm. Robotic-assisted urological procedures have gained prominence in recent years, promising enhanced precision and safety.
View Article and Find Full Text PDFSurg Endosc
March 2024
Department of Gastroenterology and Digestive Oncology, Cochin Hospital, Assistance Publique - Hôpitaux de Paris, Paris, France.
Background: Several endoscopic treatments for iatrogenic perforations are currently available, with some limitations in terms of size, location, complexity, or cost. Our aims were to introduce a novel technique for closure, using an endoloop and clips, to assess its rate of technical success and post-resection complications.
Methods: For closure of large perforations (diameter ≥ 10 mm), two similar techniques were implemented, using a single-channel endoscope.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!