Thermoluminescence dosimeter cards purchased by the US Navy in recent years have different radiation sensitivities, e.g., they exhibit a different amount of light per dose unit. Presented tests indicate that the optical transparency of the Teflon encapsulation is partially responsible for the significant variation of the DT-702/PD radiation sensitivity. It was confirmed also that the Teflon transparency is in fact a primary cause of the radiation sensitivity increase in the most recently produced dosimetric cards. This conclusion is based on the correlation found between the calibrated radiation sensitivity of the dosimeter card element and the optical transparency of its Teflon encapsulation. The transparency measurements were performed at the wavelength of 400 nm within a 10 nm spectral interval effectively covering the spectral range of the thermoluminescence. It is anticipated that the experimentally determined correlation will help to approve the acceptance of new thermoluminescence dosimeter cards in the Naval Dosimetry Center inventory as well as improve the production process.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8496950PMC
http://dx.doi.org/10.1097/HP.0000000000001149DOI Listing

Publication Analysis

Top Keywords

thermoluminescence dosimeter
12
dosimeter cards
12
radiation sensitivity
12
optical transparency
8
transparency teflon
8
teflon encapsulation
8
teflon
4
teflon transmittance
4
sensitivity
4
transmittance sensitivity
4

Similar Publications

One of the most problematic goals for radiation safety during spaceflight is an assessment of additional doses received by astronauts during extravehicular activity (EVA). The Pille-ISS thermoluminescent dosimeter developed by the predecessor of the Hungarian Research Network (HUN-REN) Centre for Energy Research (Budapest, Hungary) is designed for the routine dose measurements not only inside the spacecraft compartments, but also for personal dosimetric control for EVA. During almost two decades of the International Space Station (ISS) operation, the unique set of 131 EVA doses were recorded in different conditions, such as: solar activity, ISS trajectory along the South Atlantic Anomaly (SAA), and shielding conditions provided by two kinds of spacesuits: the Extravehicular Mobility Unit (EMU) and Orlan.

View Article and Find Full Text PDF

Objectives: Due to the increasing use of cone-beam computed tomography (CBCT) in dentistry and considering the effects of radiation on radiosensitive organs, the aim of this study was to investigate the effect of shielding on absorbed dose of eyes, thyroid and breasts in scans conducted with different parameters using two different fields of view (FOV).

Methods: Dose measurements were calculated on a tissue-equivalent female phantom by repeating each scanning parameter three times and placing at least two thermoluminescent dosimeters (TLD) on each organ, with the averages then taken. The same CBCT scans were performed in two different FOV with shielding including thyroid collar, radiation safety glasses and lead apron and without shielding.

View Article and Find Full Text PDF

The MISSE-Seed project was designed to investigate the effects of space exposure on seed quality and storage. The project tested the Multipurpose Materials International Space Station Experiment-Flight Facility (MISSE-FF) hardware as a platform for exposing biological samples to the space environment outside the International Space Station (ISS). Furthermore, it evaluated the capability of a newly designed passive sample containment canister as a suitable exposure unit for biological samples for preserving their vigor while exposing to the space environment to study multi-stressor effects.

View Article and Find Full Text PDF

A glow-curve analysis code was previously developed in C++ to analyze thermoluminescent dosimeter glow curves using automated peak detection while a first-order kinetics model. A newer version of this code was implemented to improve the automated peak detection and curve fitting models. The Stochastic Gradient Descent Algorithm was introduced to replace the prior approach of taking first and second-order derivatives for peak detection.

View Article and Find Full Text PDF

. Clinical dosimetry in the presence of a 1.5 T magnetic field is challenging, let alone in case small fields are involved.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!