Pentamode metamaterials have been used as a crucial element to achieve elastical unfeelability cloaking devices. They are seen as potentially fragile and not simple for integration in anisotropic structures due to a non-centrosymmetric crystalline structure. Here, we introduce a new class of pentamode metamaterial with centrosymmetry, which shows better performances regarding stiffness, toughness, stability and size dependence. The phonon band structure is calculated based on the finite element method, and the pentamodal properties are evaluated by analyzing the single band gap and the ratio of bulk and shear modulus. The Poisson's ratio becomes isotropic and close to 0.5 in the limit of small double-cone connections. Stability and scalability analysis results show that the critical load factor of this structure is obviously higher than the classical pentamode structure under the same static elastic properties, and the Young's modulus gradually converges to a stable value (the infinite case) with an increasing number of unit cells.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6861979PMC
http://dx.doi.org/10.3390/ma12213470DOI Listing

Publication Analysis

Top Keywords

stiffer stronger
4
stronger centrosymmetrical
4
centrosymmetrical class
4
class pentamodal
4
pentamodal mechanical
4
mechanical metamaterials
4
metamaterials pentamode
4
pentamode metamaterials
4
metamaterials crucial
4
crucial element
4

Similar Publications

Using the QM/MM methodology and a local mode analysis, we investigated a character and a strength of FeS bonds of heme groups in oxidized and reduced forms of Bacterioferritin from Azotobacter vinelandii. The strength of the FeS bonds was correlated with a bond length, an energy density at a bond critical point, and a charge difference of the F and S atoms. Changing the oxidation state from ferrous to ferric generally makes the FeS bonds weaker, longer, more covalent, and more polar.

View Article and Find Full Text PDF

Biomechanical properties of various rat rotator cuff repair techniques.

J Biomech

December 2024

Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA. Electronic address:

While rat models are frequently used to study tendon healing, there is a lack of research comparing various rotator cuff repair methods in this animal model. Determining the most effective method to begin with is pivotal for biological studies focused on healing augmentation. No study to date has shown the superiority of one repair over the other for rotator cuff repair in a rat model.

View Article and Find Full Text PDF

Purpose: Porcine cervical spines are commonly used as a surrogate for human lumbar spines due to their similar anatomic and mechanical characteristics. Despite their use in spinal biomechanics research, porcine annulus fibrosus (AF) yield and ultimate properties have not been fully evaluated. This study sought to provide a novel dataset of elastic, yield, and ultimate properties of the porcine AF loaded in the circumferential direction.

View Article and Find Full Text PDF

Cigarette Smoke Exposure Impairs Fracture Healing in a Rat Model: Preferential Impairment of Endochondral Over Membranous Healing.

J Biomech Eng

January 2025

Department of Orthopaedics and Physical Medicine, Medical University of South Carolina, Bioengineering Building 227, 68 President Street, Charleston, SC 29425; Department of Orthopaedics, Dartmouth-Hitchcock Medical Center and Geisel School of Medicine at Dartmouth, 1 Medical Center Drive, Lebanon, NH 03756.

Article Synopsis
  • Cigarette smoking negatively impacts the healing process of fractures, specifically delaying healing and increasing the risk of nonunion.
  • The study tested how cigarette smoke affects two types of bone healing (intramembranous vs. endochondral) using rat models with femur fractures treated with different methods.
  • Results showed that fractures treated with compression plating healed faster and more completely than those treated with intramedullary nailing, particularly in smoke-exposed animals, suggesting better surgical outcomes for smokers if compression plating is used.*
View Article and Find Full Text PDF

Investigation of Delamination Characteristics in 3D-Printed Hybrid Curved Composite Beams.

Polymers (Basel)

August 2024

Advanced Composites Research Group, School of Mechanical and Aerospace Engineering, Queen's University Belfast, Belfast BT9 5AH, UK.

This study focuses on understanding the impact of different material compositions and printing parameters on the structural integrity of hybrid curved composite beams. Using the continuous filament fabrication technique, which is an advanced fused deposition modelling process, composite curved beams made of short carbon and various continuous fibre-reinforced nylon laminae were fabricated and subjected to four-point bending tests to assess their delamination characteristics. The results show that the presence of five flat zones in the curved region of a curved beam achieves 10% and 6% increases in maximum load and delamination strength, respectively, against a smooth curved region.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!