A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cryostorage tank failures: temperature and volume loss over time after induced failure by removal of insulative vacuum. | LitMetric

Purpose: To determine liquid nitrogen evaporation rates of intact liquid nitrogen storage tanks and tanks with their vacuum removed.

Methods: Donated storage tank performance (LN2 evaporation) was evaluated before and after induced vacuum failure. Vacuum of each tank was removed by drilling through the vacuum port. Temperature probes were placed 2 in. below the bottom of the styrofoam cap/plug, and tanks were weighed every 3 h. Evaporation rate and time from failure to the critical temperature was determined.

Result: Storage tanks with failed vacuum have a much higher evaporation rate than those with intact vacuum; evaporation rates increased dramatically within 3 to 6 h in the smaller tanks, and time to complete depletion varied according to starting LN2 volume. Tanks with storage racks/specimens may have altered evaporation profiles compared to tanks without. Locating temperature probes 2 in. below the styrofoam cap/plug suggests that for most applications, alarms would sound approximately 1 h prior to reaching the critical warming temperature, approximately - 130 °C. External signs of vacuum loss were dramatic: vapor, frost, and audible movement of air.

Conclusion: For the first time, we have data on how liquid nitrogen storage tanks behave when their vacuum is removed. These findings are conservative; each lab must consider starting volume, tank size/capacity, function (storage or shipping), age, and pre-existing evaporation behavior in order to develop an emergency response to critical tank failure. Times to complete failure/evaporation and critical warming temperature after vacuum loss are different; these data should be considered when evaluating tank alarm systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885466PMC
http://dx.doi.org/10.1007/s10815-019-01597-5DOI Listing

Publication Analysis

Top Keywords

liquid nitrogen
12
storage tanks
12
vacuum
10
evaporation rates
8
nitrogen storage
8
tanks
8
temperature probes
8
styrofoam cap/plug
8
evaporation rate
8
critical warming
8