Response biases: the influence of the contralateral limb and head position.

Exp Brain Res

Department of Health and Kinesiology, Motor Neuroscience Laboratory, Texas A&M University, College Station, TX, 77843-4243, USA.

Published: December 2019

Two experiments were designed to determine response biases resulting from production of force in the contralateral limb and head position. Participants were required to react with one limb while tracking a sinewave template by generating a pattern of force defined by the sinewave with the contralateral limb or watching a cursor move through the sinewave. In Experiment 1, participants had to react with their right or left limb while their head was in a neutral position. In Experiment 2, participants had to react with their left limb while their head was turned 60° to the left or right. A color change of the waveform signaled participants to produce an isometric contraction with the reacting limb. Reaction time was calculated as the time interval between the color change of the waveform and the initiation of the response. The results indicated mean reaction time for the left limb was significantly influenced by force production in the right limb. During left limb reactions, reaction time was faster for trials in which both limbs initiated force simultaneously as compared to trials in which the left limb initiated force while the right limb was producing force. Mean reaction time for the right limb was not influenced by force production in the contralateral limb. The results are consistent with the notion that crosstalk can influence the time required to react to stimuli but this influence occurs at the point of force initiation and is asymmetric in nature with the dominant limb exerting a stronger influence on the non-dominant limb than vice versa. However, we did not find a similar effect for head position via the tonic neck response.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00221-019-05667-zDOI Listing

Publication Analysis

Top Keywords

left limb
20
limb
16
contralateral limb
16
limb head
16
reaction time
16
head position
12
response biases
8
force
8
required react
8
experiment participants
8

Similar Publications

Background: Autologous fat injection in facial reconstruction is a common cosmetic surgery. Although cerebral fat embolism (CFE) as a complication is rare, it carries serious health risks.

Case Summary: We present a case of a 29-year-old female patient who developed acute CFE following facial fat filling surgery.

View Article and Find Full Text PDF

A 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.

View Article and Find Full Text PDF

Objective: To evaluate the effectiveness of combination therapy based on motion feedback training in patients recovering from ischemic stroke.

Methods: A retrospective analysis was conducted on 205 patients in the recovery phase of ischemic stroke admitted between June 2022 and June 2023. Patients were divided into two groups: the conventional treatment group (n=101), receiving standard care, and the combination therapy group (n=104), receiving additional motion feedback training for 30 days.

View Article and Find Full Text PDF

Granulosa tumors are rare tumors arising from the cells of the sexual cord and stroma of the ovary. They account for 5% of ovarian cancers and 70% of stromal cancers of the sex cords. Retroperitoneal tumors (RPTs) are also rare and develop in the retroperitoneal and subperitoneal space.

View Article and Find Full Text PDF

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!