Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague description of the half-value layer procedure, we extended it to be more constrained and thus less subjective in its implementation. We specify both the measurement and data analysis steps performed in order to provide reproducible half-value layer results and compare the results with the Hp(10) dosimetry-based validation approach specified in the ISO 4037 as an alternative for field validation. Finally, we discuss the implications of our results and the extended procedure on validation and the recent changes to the ISO 4037.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncz185 | DOI Listing |
Luminescence
January 2025
Department of Physics, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
Eu-Gd co-doped glasses composed of 15BO-12SiO-(40-x)TeO-3EuO-xGdO-12BiO-8BaO-10ZnO with x = 0-4 mol% (coded as EuGd-x) were fabricated using melt quench approach to develop transparent radiation shielding system. Their structural, optical and mechanical properties were examined. 5.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physics, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia.
Glass system of 45BO-20ZnO-30BaO-5X, (where X represents CaO, MgO, AlO, TiO, CuO and FeO) in mole percentage was investigated for gamma ray radiation shielding experimentally. Six glass composites were fabricated and the density was measured experimentally and the BZBCa glass sample has the least density with a value of 3.932 g cm and this is due to the presence of CaO in it, and the sample BZBFe has the highest density with a value of 4.
View Article and Find Full Text PDFCancer Manag Res
January 2025
School of Physics, Universiti Sains Malaysia, Penang, 11800 Gelugor, Malaysia.
Introduction: Breast cancer is a significant worldwide health issue, particularly in Jordan, where early detection via mammography is essential for effective disease management. Despite the little radiation risk associated with mammography, it is crucial to monitor radiation exposure to guarantee patient safety. This study intends to assess skin entrance exposure and compute the Mean Glandular Dose (MGD) in mammography units to determine adherence to established criteria and pinpoint areas for enhancement.
View Article and Find Full Text PDFRadiat Environ Biophys
January 2025
Department of Physics, Yazd University, Yazd, Iran.
Polymer nanocomposites have been investigated as lightweight and suitable alternatives to lead-based clothing. The present study aims to fabricate flexible, lead-free, X-ray-shielding composites using a polyvinyl chloride (PVC) matrix and different nanostructures. Four different nanostructures containing impure tungsten oxide, tungsten oxide (WO), barium tungstate (BaWO), and bismuth tungstate (BiWO) were synthesized through various methods.
View Article and Find Full Text PDFSci Rep
January 2025
Raw Building Materials Technology and Processing Research Institute, Housing & Building National Research Center, HBRC, Cairo, Egypt.
Fabrication of heavy density mortar using aggregates reinforced with available solid inorganic chemical additives is of a great importance as a protective layer to mitigate radiations in nuclear facilities. The effect of lead oxide and borax decahydrate on the hydration kinetics was evaluated by determining setting time, leachability and compressive strength. To speed up the reaction, 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!